datasheetbank_Logo
búsqueda de Hoja de datos y gratuito Fichas de descarga

M37516F9-XXXHP Ver la hoja de datos (PDF) - Renesas Electronics

Número de pieza
componentes Descripción
Lista de partido
M37516F9-XXXHP
Renesas
Renesas Electronics Renesas
M37516F9-XXXHP Datasheet PDF : 90 Pages
First Prev 71 72 73 74 75 76 77 78 79 80 Next Last
7516 Group
Full Status Check
Results from executed erase and program operations can be
known by running a full status check. Figure 75 shows a flowchart
of the full status check and explains how to remedy errors which
occur.
Read status register
SR4 = 1 and YES
SR5 = 1 ?
Command
sequence error
NO
NO
SR5 = 0 ?
YES
NO
SR4 = 0 ?
YES
Erase error
Program error
Execute the clear status register command (5016)
to clear the status register. Try performing the
operation one more time after confirming that the
command is entered correctly.
Should an erase error occur, the block in error
cannot be used.
Should a program error occur, the block in error
cannot be used.
End (Erase, program)
Note: When one of SR5 to SR4 is set to 1, none of the program, erase all blocks
commands is accepted. Execute the clear status register command (5016) before
executing these commands.
Fig. 75 Full status check flowchart and remedial procedure for errors
Rev.1.01 Jul 01, 2003 page 73 of 89

Share Link: 

datasheetbank.com [ Privacy Policy ] [ Request Datasheet ] [ Contact Us ]