datasheetbank_Logo
búsqueda de Hoja de datos y gratuito Fichas de descarga

MAX2310 Ver la hoja de datos (PDF) - Maxim Integrated

Número de pieza
componentes Descripción
Lista de partido
MAX2310 Datasheet PDF : 22 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
CDMA IF VGAs and I/Q Demodulators
with VCO and Synthesizer
AC ELECTRICAL CHARACTERISTICS (continued)
(MAX2310/MAX2314 or MAX2312/MAX2316 EV kit, VCC = +2.75V, registers set to default power-up states, fIN = 210.88MHz for
CDMA, fIN = 85.88MHz for FM, fREF = 19.68MHz, synthesizer locked with passive 2nd-order lead-lag loop filter, SHDN = high, VGC
set for +35dB voltage gain, differential output load = 10kΩ, all power levels referred to 50Ω, TA = +25°C, unless otherwise noted.)
PARAMETER
VCO Minimum Divide Ratio
VCO Maximum Divide Ratio
REF Minimum Divide Ratio
REF Maximum Divide Ratio
SYMBOL
M1, M2
M1, M2
R1, R2
R1, R2
CONDITIONS
MIN TYP
16383
2047
MAX UNITS
256
2
Minimum Phase Detector
Comparison Frequency
(Note 6)
20
kHz
Maximum Phase Detector
Comparison Frequency
Base Band Spurious due to PLL
LOOUT at 85MHz,
VCO_L Enabled (Note 9)
LOOUT at 210MHz,
VCO_H Enabled (Note 9)
Charge-Pump Source/Sink
Current
Charge-Pump Source/Sink
Matching
(Note 6)
1kHz offset
12.5kHz offset
30kHz offset
120kHz offset
900kHz offset
1kHz offset
12.5kHz offset
30kHz offset
120kHz offset
900kHz offset
Acquisition, CPX = XX, TC = 1 (Note 10)
Locked, CPX = 00
Locked, CPX = 01
Locked, CPX = 10
Locked, CPX = 11
Locked, all values of CPX,
0.5V < VCP < VCC - 0.5V
1500
1480
105
150
210
300
-72
-100
-110
-119
-125
-64
-91
-105
-115
-125
2100
150
210
300
425
0.2
kHz
-50
dBc
dBc/Hz
dBc/Hz
2650
190
265
µA
380
530
10
%
Note 1: FM_IQ and FM_I modes are not available on MAX2312 and MAX2316.
Note 2: Recommended operating frequency range.
Note 3: f1 = 210.88MHz, f2 = 210.89MHz, Pf1 = Pf2 = -15dBm.
Note 4: f1 = 210.88MHz, f2 = 210.89MHz, Pf1 = Pf2 = -50dBm.
Note 5: Small-signal gain at 200kHz below the LO frequency will be reduced by less than 0.25dB when an interfering signal at
1.25MHz below the LO frequency is applied at the specified level.
Note 6: Guaranteed by design and characterization.
Note 7: f1 = 85.88MHz, f2 = 85.98MHz, Pf1 = Pf2 = -15dBm.
Note 8: f1 = 85.88MHz, f2 = 85.98MHz, Pf1 = Pf2 = -50dBm.
Note 9: Measured at LOOUT with BD = 0 (÷2 selected).
Note 10: Not available on MAX2316.
4 _______________________________________________________________________________________

Share Link: 

datasheetbank.com [ Privacy Policy ] [ Request Datasheet ] [ Contact Us ]