Adjustable, High-Linearity,
SiGe Dual-Band LNA/Mixer ICs
AC ELECTRICAL CHARACTERISTICS (continued)
(MAX232_ EV kit, VCC = +2.75V, fLNAINH = fMIXINH = 1960MHz, fLNAINL = fMIXINL = 881MHz, fLOLIN = 1091MHz (digital mode), fLOLIN =
991MHz (FM mode), fLOHIN = 1750MHz (MAX2320, MAX2322 with LOX2 = low, MAX2326 with BAND = low, MAX2327), fLLOHIN =
1085MHz (MAX2321 with BAND = low, MAX2322 with LOX2 = high), fLOHIN = 1091MHz (MAX2321 with BAND = high), fLOHIN =
2182MHz (MAX2326 with BAND = high), LO input power = -7dBm (MAX2320/MAX2326), 50system, TA = +25°C, unless otherwise
noted.) (Note 2)
PARAMETER
SYMBOL
CONDITIONS
HIGH-GAIN, LOW-LINEARITY, AND LOW-GAIN MODES (Note 1)
Gain (Note 4)
PCS
G
Without doubler
With doubler
Cellular Band
MIN -3σ TYP +3σ MAX UNITS
10.6 11.3 12 12.1 12.8
10.2 10.8 11.5 12.4 13.1
dB
11.2 12.1 13 13.8 14.7
Gain Variation Over
Temperature Relative
to +25°C
TA = -40°C to
+85°C
PCS
Cellular
±1
±1
dB
±1
±1
Noise Figure
PCS
NF
Without doubler
With doubler
(Note 7)
Cellular
Without divider
With divider
Input Third-Order
Intercept
PCS
IIP3
Cellular
Without doubler
With doubler
FM MODE (Note 1)
Gain (Note 4)
Noise Figure
G
TA = +25°C
TA = -40°C to +85°C
NF
Input Third-Order
Intercept (Notes 5, 6)
IIP3 TA = -40°C to +85°C
LO BUFFER PERFORMANCE (BUFFEN = HIGH)
LO Output Level
Load = 100pullup resistor
BUFFEN = GND
7.2
7.5
7.6
10.5 12 13.4
dB
7
7.2
7.6
7.5
7.7
8.1
+1
+2.2
dBm
+1.0
9.7 10.4 11.2 11.9 12.7
dB
7.8
9.0 11.2 14.0 15.4
10.6 11.1 11.5 dB
2.3
3.2
4.9
dBm
-12
dBm
-44
LO_OUT Even Harmonic
Distortion
-31
dBc
LO Emissions at LNA
Input Port
Interstage filter rejection = 20dB
-50
dBm
Note 1: See Tables 15 for operational mode selection.
Note 2: A total of 36 devices from 3 different wafer lots are used to determine the standard deviation. The lots were selected to rep-
resent worst-case process conditions.
Note 3: Operation is characterized for the frequencies specified in the conditions; for other frequencies in the band, see Tables 812
for LNA and mixer S parameters.
Note 4: Guaranteed by design, characterization, and production functional test.
Note 5: Guaranteed by design and characterization.
Note 6: For cellular band, RF inputs are -25dBm each tone at 881MHz and 882MHz, fLO = 1091MHz. For PCS band, RF inputs are
-25dBm each tone at 1960MHz and 1961MHz, fLO = 2170MHz. For IIP3 vs. ICC trade-off, see Typical Operating