MC-4532CD647
DC Characteristics (Recommended Operating Conditions Unless Otherwise Noted)
Parameter
Symbol
Test condition
MIN. MAX. Unit Notes
Operating current
ICC1 Burst length = 1
tRC tRC(MIN.), IO = 0 mA
/CAS latency = 2
/CAS latency = 3
1,040 mA 1
1,080
Precharge standby current in ICC2P CKE VIL(MAX.), tCK = 15 ns
16 mA
power down mode
ICC2PS CKE VIL(MAX.), tCK =
16
Precharge standby current in ICC2N CKE VIH(MIN.), tCK = 15 ns, /CS VIH(MIN.),
non power down mode
Input signals are changed one time during 30 ns.
ICC2NS CKE VIH(MIN.), tCK = Input signals are stable.
320 mA
128
Active standby current in
ICC3P CKE VIL(MAX.), tCK = 15 ns
80 mA
power down mode
ICC3PS CKE VIL(MAX.), tCK =
64
Active standby current in
non power down mode
ICC3N CKE VIH(MIN.), tCK = 15 ns, /CS VIH(MIN.),
Input signals are changed one time during 30 ns.
480 mA
ICC3NS CKE VIH(MIN.), tCK = , Input signals are stable.
320
Operating current
ICC4 tCK tCK(MIN.)
/CAS latency = 2
1,200 mA 2
(Burst mode)
IO = 0 mA
/CAS latency = 3
1,480
CBR (Auto) refresh current
ICC5 tRC tRC(MIN.)
/CAS latency = 2
2,080 mA 3
/CAS latency = 3
2,160
Self refresh current
ICC6 CKE 0.2 V
32 mA
Input leakage current
II(L) VI = 0 to 3.6 V, All other pins not under test = 0 V
– 16 + 16 µA
CKE1 – 500 +500
Output leakage current
IO(L) DOUT is disabled, VO = 0 to 3.6 V
– 3 + 3 µA
High level output voltage
VOH IO = – 4.0 mA
2.4
V
Low level output voltage
VOL IO = + 4.0 mA
0.4 V
Notes 1. ICC1 depends on output loading and cycle rates. Specified values are obtained with the output open. In
addition to this, ICC1 is measured on condition that addresses are changed only one time during tCK (MIN.).
2. ICC4 depends on output loading and cycle rates. Specified values are obtained with the output open. In
addition to this, ICC4 is measured on condition that addresses are changed only one time during tCK (MIN.).
3. ICC5 is measured on condition that addresses are changed only one time during tCK (MIN.).
6
Data Sheet E0054N20

Share Link: 