MC-4532DA726
DC Characteristics (Recommended Operating Conditions unless otherwise noted)
Parameter
Symbol
Test condition
Grade MIN. MAX. Unit Notes
Operating current
ICC1
Precharge standby current in ICC2P
Epower down mode
ICC2PS
Precharge standby current in ICC2N
non power down mode
O ICC2NS
Active standby current in
L power down mode
ICC3P
ICC3PS
Burst length = 1
tRC tRC (MIN.), IO = 0 mA
/CAS latency = 2
/CAS latency = 3
CKE VIL (MAX.), tCK = 15 ns
CKE VIL (MAX.), tCK =
CKE VIH (MIN.), tCK = 15 ns, /CS VIH (MIN.),
Input signals are changed one time during 30 ns.
CKE VIH (MIN.), tCK = ,
Input signals are stable.
CKE VIL (MAX.), tCK = 15 ns
CKE VIL (MAX.), tCK =
-A80
-A10
-A80
-A10
2,100 mA 1
2,100
2,100
2,100
268 mA
98
610 mA
224
340 mA
152
Active standby current in
ICC3N CKE VIH (MIN.), tCK = 15 ns, /CS VIH (MIN.),
790 mA
non power down mode
Input signals are changed one time during 30 ns.
ICC3NS CKE VIH (MIN.), tCK = ,
440
Input signals are stable.
P Operating current
ICC4 tCK tCK (MIN.), IO = 0 mA
/CAS latency = 2 -A80
2,190 mA 2
(Burst mode)
-A10
1,830
/CAS latency = 3 -A80
2,640
r -A10
2,280
CBR (Auto) Refresh current
ICC5
tRC tRC (MIN.)
/CAS latency = 2 -A80
4,440 mA 3
o -A10
4,440
/CAS latency = 3 -A80
4,440
-A10
4,440
d Self refresh current
ICC6 CKE 0.2 V
286 mA
Input leakage current
II (L) VI = 0 to 3.6 V, All other pins not under test = 0 V
–10 +10 µA
Input leakage current (CKE0)
–20 +20
u Output leakage current
IO (L) DOUT is disabled, VO = 0 to 3.6 V
–1.5 +1.5 µA
High level output voltage
VOH IO = –4.0 mA
2.4
V
Low level output voltage
VOL IO = +4.0 mA
0.4 V
c Notes 1. ICC1 depends on output loading and cycle rates. Specified values are obtained with the output open.
In addition to this, ICC1 is measured on condition that addresses are changed only one time during tCK (MIN.).
t 2. ICC4 depends on output loading and cycle rates. Specified values are obtained with the output open.
In addition to this, ICC4 is measured on condition that addresses are changed only one time during tCK (MIN.).
3. ICC5 is measured on condition that addresses are changed only one time during tCK (MIN.).
6