MC-45V32AD642
DC Characteristics (Recommended Operating Conditions Unless Otherwise Noted)
Parameter
Symbol
Test condition
Grade MIN. MAX. Unit Notes
Operating current (Prefetch
mode at one bank active)
ICC1P
tRC tRC (MIN.)
Prefetch is executed one time during tRC.
-A75
1,440 mA 1
Operating current (Restore
mode at one bank active)
ICC1R tRC tRC (MIN.)
-A75
1,440 mA 1
Precharge standby current
ICC2P CKE VIL (MAX.), tCK = 15 ns
19.2 mA
in power down mode
Precharge standby current
in non power down mode
ICC2PS CKE VIL (MAX.), tCK =
ICC2N CKE VIH (MIN.), tCK = 15 ns, /CS VIH (MIN.),
Input signals are changed one time during 30 ns.
19.2
320 mA
ICC2NS CKE VIH (MIN.), tCK = , Input signals are stable.
160
Active standby current in
ICC3P CKE VIL (MAX.), tCK = 15 ns
96 mA
power down mode
ICC3PS CKE VIL (MAX.), tCK =
96
Active standby current in
non power down mode
ICC3N CKE VIH (MIN.), tCK = 15 ns, /CS VIH (MIN.),
Input signals are changed one time during 30 ns.
480 mA
ICC3NS CKE VIH (MIN.), tCK = , Input signals are stable.
320
Operating current
(Burst mode)
ICC4 tCK tCK (MIN.), IO = 0 mA
Background : precharge standby
-A75
760 mA 2
Auto refresh current
ICC5
tRCF tRCF (MIN.)
-A75
2,080 mA 3
Self refresh current
ICC6 CKE 0.2 V
-A75
32 mA
Input leakage current
II (L) VI = 0 to 3.6 V, All other pins not under test = 0 V
–16
+16 µA
Input leakage current (CKE1)
–500 +500
Output leakage current
IO (L) DOUT is disabled, VO = 0 to 3.6 V
–1.5 +1.5 µA
High level output voltage
VOH IO = – 4.0 mA
2.4
V
Low level output voltage
VOL IO = + 4.0 mA
0.4
V
Notes 1. ICC1 depends on output loading and cycle rates. Specified values are obtained with the output open. In
addition to this, ICC1 is measured on condition that addresses are changed only one time during tCK (MIN.).
2. ICC4 depends on output loading and cycle rates. Specified values are obtained with the output open. In
addition to this, ICC4 is measured on condition that addresses are changed only one time during tCK (MIN.).
3. ICC5 is measured on condition that addresses are changed only one time during tCK (MIN.).
6
'DWD 6KHHW E0026N10