datasheetbank_Logo
búsqueda de Hoja de datos y gratuito Fichas de descarga

NJW1326 Ver la hoja de datos (PDF) - Japan Radio Corporation

Número de pieza
componentes Descripción
Lista de partido
NJW1326 Datasheet PDF : 16 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
NJW1326
„CHARACTERISITICS OF BUS LINES (SDA, SCL) FOR I2C BUS DEVICES
PARAMETER
SCL clock frequency
HOLD time
Low period of the SCL clock
High period of the SCL clock
Set-up time for a repeated START condition
Data Hold Time NOTE)
Data set-up Time
Rise time of both SDA and SCL signals
Fall time of both SDA and SCL signals
Set-up time for STOP condition
Bus free time between a STOP and START condition
Capacitive load for each bus line
Noise margin at the Low level
Noise margin at the High level
Cb ; total capacitance of one bus line in pF
SYMBOL
fSCL
tHD:STA
tLOW
tHIGH
tSU:STA
tHD:DAT
tSU:DAT
tr
tf
tSU:STO
tBUF
Cb
VnL
VnH
STANDARD MODE
MIN. TYP. MAX.
-
-
100
4.0
-
-
4.7
-
-
4.0
-
-
4.7
-
-
0
-
-
250
-
-
-
-
1000
-
-
300
4.0
-
-
4.7
-
-
-
-
400
0.5
-
-
1
-
-
UNIT
kHz
µs
µs
µs
µs
µs
ns
ns
ns
µs
µs
pF
V
V
NOTE) Data hold time: tHD:DAT
Please hold the Data Hold Time (tHD:DAT) to 300ns or more to avoid status of unstable at SCL falling edge.
Ver.1
-6-