ADS-325A
Re-initiating the Start-up Calibration
The start-up calibration function can be re-initiated at any time
desired after the power and the references are supplied. Apply
a positive pulse to CE pin (pin 24) or a negative pulse to
RESET pin (pin 15). The pulse width of these pulses must be
equal to or wider than one A/D clock cycle. Also due to this
feature, you can make sure of a proper start-up calibration at
power-up by making a C-R delay connection with the RESET
pin as shown in Figure 4c.
Using Start-up Calibration Function Only
Internal and external calibration functions need not be
employed after start-up calibration. To use only the start-up
calibration function, connect the SEL pin (pin 17) to AGND and
the CAL pin (pin 14) to +AVS or AGND.
Auto Calibration Function
After the start up calibration is completed, the internal
calibration function can periodically and automatically generate
calibration pulses when the auto calibration mode is enabled.
To enable this function connect the SEL pin (pin 17) and the
CAL pin (pin 41) to +AVS. In this mode a 24-bit counter is
counted with every 16 A/D clock cycles and the carry-out is
used as the calibration pulse. The period of the calibration
pulse generated is as follows:
Period of Auto-calibration pulse = 1/fCLK x 16 x 16,777,216
For the case when the A/D clock frequency is 14.3MHz, the
calibration pulse generation cycle is 18.8 seconds. Since a
single calibration process is performed once every seven
pulses, the total calibration cycle is approximately
132 seconds.
A/D CLOCK
1/16
+AVS
14-BIT COUNTER
CO
CLR
D
Q
CLR
OUT
+AVS
AGND
VRT
VRB
RESET
CE
SENSE
AMP #1
SENSE
AMP #2
24-BIT COUNTER
CO
CLR
SEL
CAL
Figure 4a Internal Calibration Pulse Generation Circuit
VOLTS
+5
1V
+2.5
+AVS
VRT
VRB
0
TIME
SENSE AMP #1
SENSE AMP #2
CLR
RESET = HIGH, CE = LOW
Figure 4b. Conditions for Start-Up Calibration
+AVS
5V
15
+AVS
VRT
RESET
VRB
CE = "L"
Figure 4c. Start-up Calibration using RESET
T PW1
T PW0
CLOCK
+1.65V
Tsd
ANALOG
INPUT
N
TDL
OUTPUT
DATA
N+1
N–3
N+2
N–2
N+3
N–1
+1.65V (+DVS = +3.3V)
+2.5V (+DVS = +5.0V)
OUTPUT
N+4
ENABLE (OE)
OUTPUT
N
DATA
ACTIVE
TPEZ
TPZE
HIGH IMPEDENCE
+1.65V (+DVS = +3.3V)
+2.5V (+DVS = +5.0V)
= SAMPLING POINT
Figure 5. ADS-325A Timing Diagrams
+1.65V (+DVS = +3.3V)
+2.5V (+DVS = +5.0V)
ACTIVE
5