MITSUBISHI <DIGITAL ASSP>
M66013FP
8-BIT I/O EXPANDER WITH ADDRESS
BASIC PROTOCOL FOR SENDING AND RECEIVING DATA
The following diagram shows the basic protocol for sending and
receiving data between the microcomputer and the M66013.
Falling of EN from "H" to "L" starts a series of sequence and rising
of EN from "L" to "H" terminates the sequence. The concrete
operation sequence is as follows:
(1) At a falling edge of EN, 8-bit parallel data of I/O pins D0 to D7
are loaded into the shift register for serial output.
(2) At a rising edge of CLK, DI pin input data is read into the shift
register for serial input and the counter for CLK counts up.
(3) When all address bits are read, a received address is compared
with an address set in the address set pin to start the specified
operation only when these addresses matches each other. The
DO pin is kept in a high impedance status until the address
comparison is complete.
When these addresses do not match, the DO pin keeps the high
impedance status until the next sequence.
(4) When the addresses match each other, the operation for
reading serial data from the DI pin and the operation for output
serial data from the D0 pin in synchronization with a falling edge
of CLK is carried out.
(5) When 16-bit data has been completely sent or received, the
following operations are carried out in synchronization with a
rising edge of EN.
(a)The DO output pin is placed in a high impedance status.
(b)When the CLK counter does not count 16 CLK rising edges,
operation (c) below is skipped and the counter is reset to
wait for the next access.
(c)When the counter value is 16, operation for writing to the
data register for parallel output, operation for output to the
I/O port or operation for setting/resetting the data setting flag
is carried out, and the counter is then reset to wait for the
next address.
EN
CLK
In the
normal mode
DI
DO
CLK
In the echo
back mode DI
DO
1T 2T 3T 4T 5T 6T 7T 8T 9T 10T 11T 12T 13T 14T 15T 16T
X A3 A2 A1 A0
Arbitrary
Address bit
C2 C1 C0
Command bit
DI7 DI6 DI5 DI4 DI3 DI2 DI1 DI0
Data bit
"Z" (High impedance status)
ACK DO7 DO6 DO5 DO4 DO3 DO2 DO1 DO0
"Z"
Acknowledge bit
Data bit
1T 2T 3T 4T 5T 6T 7T 8T 9T 10T 11T 12T 13T 14T 15T 16T
A2 A1 A0 C2 C1 C0 X X DI7 DI6 DI5 DI4 DI3 DI2 DI1 DI0
A2 A1 A0 C1 C0 DO7 DO6 DO5 DO4 DO3 DO2 DO1 DO0
"Z"
"Z"
Basic Protocol (The actual protocol differs depending on the command.)