PMB 2110
Version 1.1
Reference
4.3
Test Conditions
Unless otherwise specified, the performance indicated in this section shall be achievable
using an FR4 circuit board, with a solid ground plane as the secondary layer.
4.4
Test Circuit
PMB 2110
OUT_MIX
OUT_MIXX
Power measurement:
Each pin is measured
RF
separately, the power is
Power
Meter added to get the differential
50Ω
50Ω
output power
PMB 2110
OUT_MIX
ETC1.6-4-2-3
OUT_MIXX
RF
Spectrum
Analyzer
Harmonics measurement:
A wideband transformer is
used.
Figure 4-1 Test Circuit, differential output
Test_circuit.wmf
Specification
20
2001-07-30