datasheetbank_Logo
búsqueda de Hoja de datos y gratuito Fichas de descarga

CLM2805C Ver la hoja de datos (PDF) - Calogic, LLC

Número de pieza
componentes Descripción
Lista de partido
CLM2805C Datasheet PDF : 3 Pages
1 2 3
CLM2805
CORPORATION
ADJUSTABLE VIN = 14V, VO = 3V, IO = 10mA, R1 = 27k, C2 = 100µF, TJ = 25oC
PARAMETERS
CLM2805A/C
MIN
TYP
MAX
UNITS
Reference Voltage
1.14
1.20
1.26
V
1.08
1.32
CONDITIONS
Io 120mA, over Tem. R1 = 27K
ADJUSTABLE VERSION ONLY VIN = 14V, VO = 3V, IO = 10mA, R1 = 27k, C2 = 100µF, TJ = 25oC
PARAMETERS
CLM2805C
MIN
TYP
MAX
UNITS
CONDITIONS
Output Voltage Range
3.0
24
V
Line Regulation
Load Regulation
Output Impedance
Quiescent Current
Output Noise Voltage
0.2
1.5
0.3
1.0
40
0.4
1.0
15
0.8
1.0
100
mV
% max
m/V
mA
µVrms/V
VOUT+0.6V<VIN<26V
5mA<IO<100mA
100mA DC and 10mA rms, 100Hz - 10kHz
IO = 10mA
IO = 120mA
During Shutdown RL = 500
10Hz - 100kHz
Long Term Stability
0.4
%/1000h
Ripple Rejection
Dropout Voltage
Maximum Operational Input Voltage
0.02
0.05
0.2
0.3
0.6
26
33
%/V
fO = 120Hz
IO = 10mA
IO = 120mA
V
Maximum Line Transient
Reverse Polarity Input Voltage, DC
Reverse Polarity Input Voltage, Transient
On/Off Threshold Current
Threshold Voltage On
Threshold Voltage Off
60
70
-15
-30
-50
-80
20
50
2.0
1.2
3.25
2.2
IO = 10mA, Reference Voltage <1.5V
VO>0.3V, RL = 500
1% Duty Cycle, T<100ms, RL = 500
µA
V
VO = 3V
Notes:
1. See TYPICAL APPLICATIONS notes to ensure constant junction temperature, low duty cycle pulse testing used.
2. All limits are at 125oC or over the full operating temperature junction range of -40oC to +125oC.
3. The maximum power dissipation is a function of maximum junction temperature, total thermal resistance and ambient temperature.
4. Human body model, 100µF discharged through 1.5K.
CALOGIC CORPORATION, 237 Whitney Place, Fremont, California 94539, Telephone: 510-656-2900, FAX: 510-651-3025