datasheetbank_Logo
búsqueda de Hoja de datos y gratuito Fichas de descarga

STLC3075(2005) Ver la hoja de datos (PDF) - STMicroelectronics

Número de pieza
componentes Descripción
Lista de partido
STLC3075
(Rev.:2005)
ST-Microelectronics
STMicroelectronics ST-Microelectronics
STLC3075 Datasheet PDF : 26 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
STLC3075
The metering pulse is obtained starting from two logic signals:
CKTTX: is a square wave at the TTX frequency (12 or 16KHz) and should be permanently applied to
the CKTTX pin or at least for all the duration of the TTX pulse (including rising and decay phases).
D0: enable the TTX generation circuit and define the TTX pulse duration.
These two signals are processed by a dedicated circuitry integrated on chip that generate the metering
pulse as an amplitude modulated shaped squarewave (SQTTX) (see fig. 7).
Both the amplitude and the envelope of the squarewave (SQTTX) can be programmed by means of ex-
ternal components. In particular the amplitude is set by the two resistors RLV and the shaping by the ca-
pacitor CS.
Figure 7. Metering pulse generation circuit.
CTTX1
Low Pass Filter
C1
BURST
SHAPING CS
GENERATOR
RLV
SQTTX
RLV
CTTX2
-
R1 R2 FTTX OP1
+
RTTX
CFL
C2
Sinusoidal wave
pulse metering
Required external components vs. filter order.
D0
CKTTX
Square wave pulse metering
Order CFL R1 C1 R2 C2 THD
1
X
13%
2
X
X
X
X 6%
3
X
X
X
X
X 3%
The waveform so generated is then filtered and injected on the line.
The low pass filter can be obtained using the integrated buffer OP1 connected between pin FTTX (OP1
non inverting input) and RTTX (OP1 output) (see fig. 7) and implementing a "Sallen and Key" configura-
tion. Depending on the external components count it is possible to build an optimised application depend-
ing on the distortion level required. In particular harmonic distortion levels equal to 13%, 6% and 3% can
be obtained respectively with first, second and third order filters (see fig. 7).
The circuit showed in the "Application diagram" is related to the simple first order filter.
Once the shaped and filtered signal is obtained at RTTX buffer output it is injected on the TIP/RING pins
with a +6dB gain or +12dB gain.
It should be noted that this is the nominal condition obtained in presence of ideal TTX echo cancellation
(obtained via proper setting of RTTX and CTTX).
In addition the effective level obtained on the line will depend on the line impedance and the protection re-
sistors value. In the typical application (TTX line impedance =200, RP = 50, and ideal TTX echo cancel-
lation) the metering pulse level on the line will be 1.33 or 2.66 times the level applied to the RTTX pin.
As already mentioned the metering pulse echo cancellation is obtained by means of two external compo-
nents (RTTX and CTTX) that should match the line impedance at the TTX frequency. This simple network
has a double effect:
Synthesize a low output impedance at the TIP/RING pins at the TTX frequency.
Cut the eventual TTX echo that will be transferred from the line to the TX output.
8/26

Share Link: 

datasheetbank.com [ Privacy Policy ] [ Request Datasheet ] [ Contact Us ]