TSM121
PIN DESCRIPTION
Name
Vcc
Gnd
Vs12
Vs5
Vs33
Tuv
EP
Is12
Is5
Is33
PI
PG
Tpg
REM
Trem
Tsur
Vref2
IN+
IN-
FB
OSC
SS/DTC
C1
C2
Pin #
Type
Function
2 Power Supply
21 Power Supply
Positive Power Supply line.
Ground. 0V Reference for all voltages.
Housekeeping
15 Analog input
14 Analog input
13 Analog input
18 Timing capacitor
16 Analog input
10 Analog input
11 Analog input
12 Analog input
17 Analog input
9 Open Collector
8 Timing capacitor
6 TTL input
7 Timing capacitor
19 Analog input
Over & under voltage sense input dedicated to the 12V line
Over & under voltage sense input dedicated to the 5V line
Over & under voltage sense input dedicated to the 3.3V line
Adjustable Under voltage blanking delay at Power Up (setting capacitor)
Extra Protection (Over voltage for -5V and/or -12V line or Primary
OverPower protection). If this extra Protection circuit is not used, pin EP
should be connected to Vref2
Over current sense input dedicated to the 12V line
Over current sense input dedicated to the 5V line
Over current sense input dedicated to the 3.3V line
Power Good input. This pin detects the power conditions.
Power Good output. PG output is High when the power conditions are OK.
Adjustable Power Good delay (setting capacitor)
Input Remote control of the complete system by the motherboard
(µController). Remote is active high. Switch OFF/ON of the Power Supply.
Reset of the complete system after a FAULT activation.
Adjustable Remote delay (setting capacitor)
Inrush Current Blank (surge) setting resistor and capacitor input. Avoids
that the Housekeeping protection latches on normal start up surge
conditions.
PWM
20 Voltage Reference Voltage Reference for all the PWM section. Vref2 is uncommitted to Vref1
(Housekeeping section). Vref2 should be connected to a decoupling
capacitor (0.1µF)
5 Opamp input
Positive Input of the error amplifier
4 Opamp input
Negative Input of the error amplifier
3 Feedback
Feedback input of the error amplifier
22 Timing capacitor Frequency setting capacitor input
23 Analog input
Soft Start. Imposes progressive increase of the switching duty cycle to
avoid current inrush at power up. When SS/DTC is high, duty cycle is low.
When SS/DTC is low, duty cycle is high. Dead Time Control. Limits the
maximum duty cycle to a programmable level using appropriate external
bridge resistor.
1 Open Collector
Output Drive (to Pulse Transformer. Open Collector 1)
24 Open Collector
Output Drive (to Pulse Transformer. Open Collector 2)
2/12