LINEAR INTEGRATED CIRCUIT
ABSOLUTE MAXIMUM RATINGS
PARAMETER
SYMBOL
RATING
UNIT
Input Voltage
VIN
-0.3~12
V
Power Dissipation
Junction Temperature
Operation Temperature
Storage Temperature
PD
300
mW
TJ
+125
°C
TOPR
-20~+125
°C
TSTG
-40~+150
°C
Note: 1.Absolute maximum ratings are those values beyond which the device could be permanently damaged.
Absolute maximum ratings are stress ratings only and functional device operation is not implied.
2.The device is guaranteed to meet performance specification within 0~ +70operating temperature
range and assured by design from -20~ +125.
ELECTRICAL CHARACTERISTICS(Ta=25°C, CIN=1µF, COUT=10µF, unless otherwise specified)
FOR VOUT<3.3V (VOUT±2%)
PARAMETER
Output Voltage
Output Voltage Temperature Coefficient
Line Regulation
Load Regulation (note 2)
Current Limit (note 3)
Dropout Voltage (note 4,5)
Standby current
SYMBOL TEST CONDITIONS
VOUT IL=2mA, VIN-VOUT=2V
TCVO
VOUT
IL=2mA,
VIN-VOUT=2V~VIN=9V
VOUT
IL=2mA~200mA,
VIN-VOUT =2V
IL VIN-VOUT=2V, VOUT=0V
VD
ISTN-BY IL=0, VIN=9V
MIN TYP. MAX UNIT
VOUT×0.98 VOUT VOUT×1.02 V
50
150 PPM/°C
0.5
%VOUT
10
30
mV
300
mA
1.5
V
3.0
mA
FOR ADJ and VOUT3.3V (VOUT±2%)
PARAMETER
SYMBOL TEST CONDITIONS
MIN TYP. MAX UNIT
Output Voltage
VOUT IL=2mA, VIN-VOUT=2V
VOUT×0.98 VOUT VOUT×1.02 V
Adjustable (R1=120,R2=200,VOUT=3.3V)
Reference Voltage
VREF VIN-VOUT=2V, IL=2mA
1.238 1.250 1.262
V
Output Voltage Temperature Coefficient TCVO
50
150 PPM/°C
Line Regulation
VOUT
IL=2mA,
VIN-VOUT=2V~VIN=12V
0.5
%VOUT
Load Regulation (note 2)
VOUT
IL=2mA~200mA,
VIN-VOUT=2V
10
30
mV
Current Limit (note 3)
IL VIN-VOUT=2V, VOUT=0V
300
mA
Dropout Voltage (note 4,5)
VD
1.3
V
Standby current
ISTN-BY IL=0, VIN=12V
5.0
mA
Note 1: Guaranteed by design.
Note 2: Regulation is measured at constant junction temperature, using pulsed on time.
Note 3: Current limit is measured at constant junction temperature, using pulsed on time.
Note 4: Dropout is measured at constant junction temperature, using pulsed on time, and the criterion is VOUT inside
target value±2%.
Note 5: Dropout test is skipped at the condition of VIN<3V.