1.3. Offset and sensitivity calibration
Vout offset is calibrated in 0g position:
Offset = Vout (0g ) [V]
Nominal offset is Vdd/2:
Offset nom
= Vdd
2
[V]
Sensitivity is calibrated as:
Sensitivity = Vout (+ 1g ) Vout (1g ) [V/g]
2g
Nominal sensitivity is:
Sensitivitynom = 1,2 [V/g]
SCA610-E28H1A
1.4. Error calculations
Total error is the allowed maximum error, which include partial error sources. Total error over
lifetime is specified as a sum of offset and sensitivity errors:
Total _ Error = Offset _ Error + Sensitivity _ Error [mg]
Offset error is specified as:
Vout(0g ) Vdd
Offset _ Error =
2 [mg]
Sensitivity
Sensitivity error percent is specified as:
Sensitivity _ Error% = [Vout(+ 1g ) Vout(1g )] 2 g Sensitivitynom ×100%
Sensitivitynom
Sensitivity error is specified as:
[Vout Vout(0g )]× Sensitivity _ Error%
Sensitivity _ Error =
[mg]
Sensitivity