Parameter and Conditions
at Tj = 25 °C, Vbb = 12 V unless otherwise specified
Symbol
BTS 426 L1
Values
Unit
min typ max
Input and Status Feedback11)
Input resistance
RI
Tj=-40..150°C, see circuit page 6
Input turn-on threshold voltage Tj =-40..+150°C: VIN(T+)
Input turn-off threshold voltage Tj =-40..+150°C: VIN(T-)
Input threshold hysteresis
VIN(T)
Off state input current (pin 2), VIN = 0.4 V,
Tj =-40..+150°C
IIN(off)
On state input current (pin 2), VIN = 3.5 V,
Tj =-40..+150°C
IIN(on)
Delay time for status with open load after switch
off
(see timing diagrams, page 11), Tj =-40..+150°C
Status invalid after positive input slope
(open load)
Tj=-40 ... +150°C:
Status output (open drain)
td(ST OL4)
td(ST)
Zener limit voltage Tj =-40...+150°C, IST = +1.6 mA: VST(high)
ST low voltage Tj =-40...+25°C, IST = +1.6 mA: VST(low)
Tj = +150°C, IST = +1.6 mA:
2.5 3.5
6 k
1.7
-- 3.5 V
1.5
--
-- V
-- 0.5
-- V
1
-- 50 µA
20 50 90 µA
100 520 1000 µs
-- 250 600 µs
5.4 6.1
-- V
--
-- 0.4
--
-- 0.6
11) If a ground resistor RGND is used, add the voltage drop across this resistor.