datasheetbank_Logo
búsqueda de Hoja de datos y gratuito Fichas de descarga

MPB125 Ver la hoja de datos (PDF) - Power-One Inc.

Número de pieza
componentes Descripción
Lista de partido
MPB125
Power-One
Power-One Inc. Power-One
MPB125 Datasheet PDF : 9 Pages
1 2 3 4 5 6 7 8 9
MPB125 Multiple-Output AC-DC Series Data Sheet
Interface Signals and Internal Protection (Cont.)
PARAMETER
Power Good Signal
CONDITIONS/DESCRIPTION
MIN
NOM
MAX
UNITS
AC/DC indicator - This signal indicates the status of the AC input or DC outputs.
When there is sufficient AC voltage and the outputs are operating normally, an
open collector signal is provided.
Turn-On delay time from application of AC:
50
500
Warning time before outputs go out of regulation:
5
ms
Warning time before outputs deviate ±10% from the nominal value:
15
Sync Current
20
mA
Pull-up Voltage
30
V
Power Supply OK Signal
Provided on dual-output models. Open collector signal intended to drive an LED.
Closed collector occurs when the Power Good Signal is in its open collector state.
Sync Current
Pull-up Voltage
20
mA
30
V
Thermal Shutdown
Current Share
Isolation Diode
Protected against overtemperature conditions.
Unit recovers when overtemperature condition is removed.
Provided on dual-output models. Up to 4 units can be connected in parallel.
There are some limits for parallel operation. See MPB125 Applications Note.
N+1 redundancy is provided. V2 needs an external isolation diode for N+1 operation.
An external diode is required on MPB125-2003 and MPB125-2005 models for
redundancy on both V1 and V2, or when ordering, you can specify MPB125-2003D or
-2005D which have an internal isolation diode.
Internal isolation diode is provided on V1 for all dual-output models except the
MPB125-2003 and MPB125-2005. Specify MPB125-2003D or MPB125-2005D,
respectively, if an internal isolation diode is required for these models.
Safety, Regulatory, and EMI Specifications
PARAMETER
CONDITIONS/DESCRIPTION
MIN
NOM
MAX
UNITS
Agency Approvals
UL60950-1.
CSA 22.2 No. 60950-1.
EN60950 (TÜV).
IEC60950-1.
Dielectric Withstand Voltage
AC to chassis.
Input to output.
1500
VAC
3000
VDC
Electromagnetic Interference EN55022 Conducted.
B
Class
ESD Susceptibility
Per EN61000-4-2, Level 4
8
kV
Flicker
Per EN61000-3-3.
Radiated Susceptibility
Per EN61000-4-3.
3
V/m
EFT/Burst
Per EN61000-4-4.
1
kV
Input Transient Protection
Per EN61000-4-5, Level 3, 2 kV (Line-to-Gnd) minimum, 1 kV (Line-to-Line) minimum.
RF Immunity
Per EN61000-4-6. 0.15 to 80 MHz (1 kHz sinewave)
3
V/m
Magnetic Fields
Per EN61000-4-8.
1
A/m
Voltage Dips
Per EN61000-4-11.
Insulation Resistance
Input to output.
10
M
Leakage Current
Per EN60950 (264 VAC)
1.0
mA
OCT 24, 2005 revised to JUN 05, 2006
Page 3 of 9
www.power-one.com

Share Link: 