8 ELECTRICAL SPECIFICATIONS
Table 5. Absolute Maximum Ratings (refer to Notes 1 and 2)
Symbol
Parameters
Value
Unit
Vdd
2.5 V Power Supply Voltage
2.5 V Input or Output Voltage
Vdd
3.3 V Power Supply Voltage
3.3 V Input or Output Voltage
-0.5 to 3.3
V
-0.5 to (Vdd + 0.5)
V
-0.5 to 4
V
-0.5 to (Vdd3 + 0.5)
V
Notes: 1. Referenced to Vss. Stresses above those listed under “absolute Maximum Ratings” may cause permanent damage to the device.
This is a stress rating only and functional operation of the device at these or any other conditions above those indicated in the
operation sections of this specification is not implied. Exposure to absolute maximum rating conditions for extended periods may
affect the device reliability.
2. A dedicated 3.3 V power supply is needed for 3.3 V inputs and outputs.
Table 6. Recommended DC Operating Conditions
Main Supply Normal Range Operating Voltage Vdd
(refer to note 1)
2.5 V +/- 10% (2.25 V to 2.75 V)
Additional Ring Supply Voltage (refer to notes 1 and 2)
3.3 V + 0.3V/-0.6 V (2.7 V to 3.6 V)
Main Supply Extended Range Operating Voltage
(refer to notes 1 and 3)
2.5 V +/- 10% -28% (1.8 V to 2.75 V)
Operating Ambient Temperature
Commercial (refer to note 4)
Industrial (refer to note 4)
Military (refer to note 5)
0 to 70 degrees Centigrade
-40 to +85 degrees Centigrade
-55 to +125 degrees Centigrade
Notes: 1. Commercial, Industrial, and Military Conditions.
2. Mandatory for 3.3 V buffers only.
3. 3 V buffer specifications are not applicable for main supply below 2.25 V.
4. All circuits will operate to full specifications with a junction temperature of -40 to +125 degrees centigrade. These junctio n temper-
atures are compatible with the Commercial and Industrial Temperature Ranges.
5. All circuits will be functional from -55 to +150 degrees centigrade junction temperature (military Ambient Temperature Range) but
will not necessary operate to published specifications. Only circuits specified as operational to extended temperature range may
be used when operating to Military temperature conditions.
Table 7. General Interface DC Electrical Characteristics
Symbol
Parameter
Conditions
Min.
Type
Max
Unit
Iil
Low level input current
without pull-up device
Vi = 0 V
11
µA
Iih
High level input current
without pull-down device
Vi = Vdd
11
µA
Iox
Tri-state output leakage without pull up/ Vo = 0 V or Vdd
down device
11
µA
Cin
Input capacitance
Cout
Output capacitance
Cio
I/O capacitance
Ilatchup I/O latch-up current
V < 0 V; V > Vdd2
5003
mA
Vexd
Electrostatic protection4
Leakage < 1 µA
4000
V
1) The leakage currents are generally very small (<1 an). The value given here, 1 µA, is the maximum that can occur after an
electrostatic stress on the pin.
2) V > Vdd3 for 3.3 V buffers.
3) V > Vdd3 for 3.3 V buffers.
4) Human body model.