XE2420G Modem S-Registers (continued)
S24 Sleep Inactivity Timer: S24 determines the length
of inactivity before the modem enters sleep mode.
When set to 0, sleep mode is disabled.
Range: 0 to 255
Units: Seconds
Default: 0
S30 Disconnect Inactivity Timer: S30 controls how
long the modem will remain on line with no data
flowing. A 0 disables the inactivity time out.
Range: 0-255
Units: Minutes
Default: 0
S38 Hang Up Delay Timer: S38 determines the
maximum delay between receipt of the ATH0
command and modem disconnect. .
Range: 0-255
Units: Seconds
Default: 20
S42 Blacklisting - S42 controls the Blacklisting function
within the XE2420G. Blacklisting regulates how
frequently the modem can dial the same number. An
attempt to dial beyond the limit will result in the
“BLACKLISTED” result code being sent.
S42 = 0 Disabled
S42 = 1 Enabled
Default: 0
S43 Dial Attempts before Blacklisting - S44 determines
how many dial attempts will be allowed before
Blacklisting blocks a call
Range: 0-4
Units: Number of Calls
Default: 4
S44 Blacklisting Timer - S44 sets the duration of the
Blacklisting period.
Range: 0-255
Units: Seconds
Default: 180
S50 Minimum Off-Hook Duration - S50 determines the
minimum length of time the modem will remain off-
hook. An attempt to drop the line before this timer
expires, will be ignored by the modem until the timer
expires.
Range: 0-255
Units: Seconds
Default: 3