datasheetbank_Logo
búsqueda de Hoja de datos y gratuito Fichas de descarga

CX12(2002) Ver la hoja de datos (PDF) - ProTek Devices.

Número de pieza
componentes Descripción
Lista de partido
CX12
(Rev.:2002)
Protek-Devices
ProTek Devices. Protek-Devices
CX12 Datasheet PDF : 2 Pages
1 2
DEVICE CHARACTERISTICS
CX12
and
CX12LC
MAXIMUM RATINGS @ 25°C
ELECTRICAL CHARACTERISTICS @ 25°C
Peak Operating Line Voltage (V OP )
Operating Line Current (I O )
Maximum Transient Voltage
Maximum Transient Current
Maximum Leakage Current
CX12 Frequency Responce -3 dB
CX12LC Frequency Responce -3 dB
Operating & Storage Temperature
Response Time
±12 V
200mA
20kV
3000A (8/20µs)
5µA
@ 30MHz
@ 200MHz
-40° to +85°C
< 10 ns
PROTEK
PART
NUMBER
CX12
CX12LC
MAXIMUM
CLAMPING
* VOLTAGE
Line-Ground
500A @ 8/20 ms
VC
VOLTS
24
28
MAXIMUM
LINE
THRUPUT
RESISTANCE
R
OHMS
3
10
* Other Voltages Available Consult Factory
Frequency Responce CX12
TYPICAL
CAPACITANCE
@ 0 V, 1 MHz
C
pF
200
25
1.21
(30.73 mm)
Frequency Responce CX12LC
0.15
(3.81mm)
1.10
(27.94 mm)
1.40
(35.56 mm)
1.10
(27.54 mm)
0.72
(18.29 mm)
INSTALLATION
The CX12 series is designed with a female BNC type connector on both ends for
easy installation. Disconnect the video or data line from the sensitive equipment.
Insert the CX12 in the line near the AC power outlet of the equipment to be
protected. Install a cable in between the CX12 and the equipment to be pro-
tected. Attach a ground wire between the case of the CX12 and the equipment AC
power ground, or to the coax shield as required.
05017.R2 7/02
2
2.25
(57.15 mm)
EQUIPMENT
0.72
(18.29 mm)
www.protekdevices.com

Share Link: 

datasheetbank.com [ Privacy Policy ] [ Request Datasheet ] [ Contact Us ]