MAX2640/MAX2641
300MHz to 2500MHz SiGe
Ultra-Low-Noise Amplifiers
Pin Description
IN
NAME
FUNCTION
1
RFIN
Amplifier Input. AC-couple to this pin with a DC blocking capacitor. Use recommended input matching
network (see Typical Operating Circuit).
2, 3, 5 GND Ground. For optimum performance, provide a low inductance connection to the ground plane.
4
RFOUT Amplifier Output. Use the recommended series blocking or matching capacitor (see Typical Operating Circuit).
Supply Voltage. Bypass to ground directly at the supply pin. The value of the bypass capacitor is determined by
6
VCC
the lowest operating frequency. Additional bypassing may be necessary for long VCC lines (see Typical Operating
Circuit).
Detailed Description
The MAX2640 and MAX2641 are ultra-low-noise ampli-
fiers that operate with RF input frequency ranges
of 300MHz to 1500MHz (MAX2640) or 1400MHz to
2500MHz (MAX2641). These devices are available in
SOT23-6 packages and contain internal bias circuitry to
minimize the number of required external components.
Their small size and low external component count make
them ideal for applications where board space is limited.
Applications Information
External Matching Components
The MAX2640/MAX2641 are easy to use, generally
requiring only five external components as shown in
the Typical Operating Circuit. To reduce external com-
ponent count further, replace external inductors with
microstrip transmission lines. The high reverse isola-
tion allows the tuning of the input matching network
without affecting the output match, and vice versa.
Select input and output matching networks to obtain the
desired combination of gain, noise figure, and return
loss performance. The Typical Operating Circuit show
the recommended input and output matching networks
for the MAX2640/MAX2641 at 900MHz and 1900MHz,
respectively. These values are optimized for best
simultaneous gain, noise figure, and return loss per-
formance. To aid in the design of matching networks
for other frequencies, Tables 1 and 2 list typical device
S-parameters and Tables 3 and 4 list typical device noise
parameters.
www.maximintegrated.com