CONTINUOUS CURRENT RATINGS - POWER CONTACT CODE SELECTION
NOTES:
1. Current ratings:
• First number represents current rating per pole for 30°C temperature rise (25 / 38)
• Second number is the maximum recommended current per pole based on a 25°C ambient (25 / 38)
2. Configuration H - N based on signal contacts crimped to #20 AWG wire and carrying 1 amp
3.
Denotes wire size not appropriate for power contact
4. Shaded boxes
are
pending.
5. 1827G1 housing should be used with 1830G1 or 1830G2 ground contact, depending on primary contacts
(see chart above). All signal housings (4850) come with two 4802G3 and two 4803G3 contacts.
HOLDER LOCATIONS (VIEWS)
Front
Back
Front Back
Receptacle
12
34
21
43
Plug
21
43
12
34
TEMPERATURE CHART
SPEC Pak(4) Pole - Temperature Rise
Based on 261G2 Contact
50
40
30
20
10
0
0
5 10 15 20 25 30 35 40
Amperes
#10 AWG
#12 AWG
#14 AWG
www.andersonpower.com - 9 -