datasheetbank_Logo
búsqueda de Hoja de datos y gratuito Fichas de descarga

XE5620 Ver la hoja de datos (PDF) - Xecom

Número de pieza
componentes Descripción
Lista de partido
XE5620 Datasheet PDF : 18 Pages
First Prev 11 12 13 14 15 16 17 18
XE5620 AT Commands
&Kn - Flow Control
n=0 No Flow Control
n=3 RTS/CTS Flow Control *
n=4 XON/XOFF Flow Control
n=5 Transparent XON/XOFF Flow Control
&Pn - Pulse Dial Make/Break Ratio
n=0 39%/61% 10 PPS *
n=1 33%/67% 10 PPS
n=2 39%/61% 20 PPS
n=3 33%/67% 20 PPS
&Sn - Data Set Ready
n=0 Data Set Ready Forced Active *
n=1 Data Set Ready on at Start of Modem handshake
&Un - Protocol Selection
n=0 V.90 *
n=1 V.34Bis/V.34
n=2 V.32bis/V.22bis
n=3 Bell 103
n=4 V.21
n=5 V.23
&V - View Active Configuration
&Wn - Store Current Configuration
n=0 Store Active Configuration in Profile 0 *
n=1 Store Active Configuration in Profile 1
&Yn - Select Configuration to Recall
n=0 Recall Configuration Profile 0 *
n=1 Recall Configuration Profile 1
&Zn=x - Store dialing string x
%Cn - Data Compression Control
n=0 No Data Compression
n=1 Data Compression Enabled *
\Nn - Error Control Mode
n=0 Normal Mode
n=1 Direct Mode
n=2 MNP Required
n=3 MNP or Normal
n=4 Auto Error Correction V.42 without ODP or ADP
Phase Detection, MNP or Normal mode
n=5 Auto Reliable Mode *
n=6 V.42 without ODP or ADP Phase Detection required
n=7 V.42 with ODP or ADP Phase Detection required
\Vn - Protocol Result Code
n=0 No Protocol Result code added to Response *
n=1 Protocol Result code added to Response
*Hn - Automatic Retrain
n=0 Automatic Retrain Disabled
n=1 Automatically retrain on poor signal quality
*In - Select Maximum Connection Speed
n=0 1200 BPS,
n=1 2400 BPS,
28,000 with AT&U=0
n=2 4800 BPS,
29,333 with AT&U=0
n=3 7200 BPS,
30,666 with AT&U=0
n=4 9600 BPS,
32,000 with AT&U=0
n=5 12,000 BPS,
33,333 with AT&U=0
n=6 14,400 BPS,
34,666 with AT&U=0
n=7 16,800 BPS,
36,000 with AT&U=0
n=8 19,200 BPS,
37,333 with AT&U=0
n=9 21,600 BPS,
38,666 with AT&U=0
n=10 24,000 BPS,
40,000 with AT&U=0
n=11 26,400 BPS,
41,333 with AT&U=0
n=12 28,800 BPS,
42,666 with AT&U=0
n=13 31,200 BPS,
44,000 with AT&U=0
n=14 33,600 BPS *, 45,333 with AT&U=0
n=15 46,666 BPS with AT&U=0
n=16 48,000 BPS with AT&U=0
n=17 49,333 BPS with AT&U=0
n=18 50,666 BPS with AT&U=0
n=19 52,000 BPS with AT&U=0
n=20 53,333 BPS with AT&U=0
n=21 54,666 BPS with AT&U=0
n=22 56,000 BPS with AT&U=0 *
*Hn - Automatic Retrain
n=0 Automatic Retrain Disabled
n=1 Automatically retrain on poor signal quality *
XECOM
(11)
XE5620

Share Link: 

datasheetbank.com [ Privacy Policy ] [ Request Datasheet ] [ Contact Us ]