Demagnetisation of inductive loads
Demagnetisation of inductive loads
The L6377 has an internal clamping zener diode able to demagnetise inductive loads. Note
that the limitation comes from the peak power that the package can handle. Attention must
be paid to a proper thermal design of the board. If, for whatever reason (load current or
inductive value too big) the peak power dissipation is too high, an external Zener plus Diode
arrangement, can perform a demagnetisation versus Ground or versus Vs (see fig 5 and 6).
The breakdown voltage of the external Zener Diode must be chosen considering the internal
clamping voltage (Vcl) and the supply voltage (Vs) according to:
Vz < Vcl(min)-Vs(max)
for demagnetisation versus ground or
Vs(max)<Vz<Vcl(min)
for demagnetisation versus Vs.
Figure 6. Input comparator hysteresis
Vout
100mV 100mV
Vs
Vi-
D94IN079
Vi+
Figure 7. External demagnetisation circuit (versus ground)
DRIVER
VS
RS
CURRENT
OVC
LIMIT
UV
SHORT CIRCUIT
CONTROL
OUT
VZ
VZ < Vcl (min) - VS (max)