Recommended Operating Conditions
Symbol
VCC
TA
Parameter
Power Supply Voltage
Ambient Temperature
A Product Line of
Diodes Incorporated
AP1695
Min
Max
Unit
7
25
V
-40
+105
°C
Electrical Characteristics (@TA = +25°C, unless otherwise specified.)
Symbol
Parameter
Conditions
UVLO Section
VTH (ST)
Start-up Threshold
–
VOPR (Min)
Minimum Operating Voltage
After turn on
VCC_OVP
VCC OVP Voltage
–
–
VCC Delatch Voltage (Note 5)
–
Standby Current Section
IST
Start-up Current
ICC (OPR)
Operating Current
VCC = VTH (ST)-0.5V,
Before start up
Static
Current Sense Section
VCS_REF
Current Sense Reference
–
Current Sense Reference
VCS_CLAMP
Clamp
–
tONP_MIN
Minimum tONP
–
tD(H-L)
Delay to Output (Note 5)
–
Feedback Input Section
IFB
VFB_CV
Feedback Pin Input Leakage
Current
FB CV Threshold
VFB = 2V
–
VFB_OVP
FB OVP Threshold
–
Internal MOSFET Section
RDS(ON)
Drain-Source On-State Resistance VGS = 10V, ID = 1.25A
VBR(Drain)
Drain-Source Breakdown Voltage
VGS = 0V, ID = 250µA
IDSS
Drain-Source Leakage Current
VDS = 500V, VGS = 0V
Output Current
System Output Current On Final
–
–
Test Board
Over Temperature Protection Section
–
Shutdown Temperature (Note 5)
–
–
Temperature Hysteresis (Note 5)
–
Note 5: These parameters, although guaranteed by design, are not 100% tested in production.
.
AP1695
Document number: DS37312 Rev. 1 - 2
5 of 15
www.diodes.com
Min
13
5.5
27
3
–
–
–
1.2
700
50
–
3.8
4.5
–
500
–
–
+150
–
Typ
14.5
6.5
29
4
–
900
1
1.4
–
150
–
4
6
–
–
–
–
–
+20
Max
Unit
16
V
7.5
V
31
V
5
V
20
µA
1300
µA
–
V
–
V
1000
ns
250
ns
4
µA
4.2
V
7.5
V
6
Ω
–
V
1
µA
±2
%
–
°C
–
°C
June 2014
© Diodes Incorporated