ACS120
Characteristics
Symbol
IGT
VGT
VGD
IH
IL
VTM
VTO
Rd
IDRM / IRRM
dV/dt
(dV/dt)c
(dI/dt)c
VCL
ICL
Table 4. Parameter description
Parameter description
Triggering gate current
Triggering gate voltage
Non-triggering gate voltage
Holding current
Latching current
Peak on-state voltage drop
On state threshold voltage
On state dynamic resistance
Maximum forward or reverse leakage current
Critical rate of rise of off-state voltage
Critical rate of rise of commutating off-state voltage
Critical rate of decrease of commutating on-state current
Clamping voltage
Clamping current
Table 5. Electrical characteristics
Symbol
Test conditions
IGT
VGT
VGD
IH
IL
VTM
VTO
Rd
VOUT = 12V (DC), RL = 140 Ω
VOUT = 12V (DC), RL = 140 Ω
VOUT = VDRM, RL = 3.3 kΩ
IOUT = 100 mA gate open
IG = 20 mA
IOUT = 2.8 A, tp = 380 µs
IDRM /IRRM VOUT = 700 V
dV/dt
(dI/dt)c
VCL
VOUT = 460 V gate open
(dV/dt)c = 20 V/µs
ICL = 1 mA, tp = 1 ms
QII -QIII
TJ = 25°C
Max
QII -QIII TJ = 25 °C Max
TJ = 125 °C Min
TJ = 25 °C Max
TJ = 25 °C Max
TJ = 25 °C Max
TJ = 125 °C Max
TJ = 125 °C Max
TJ= 25 °C
Max
TJ = 125 °C Max
TJ = 110 °C Min
TJ = 125 °C Min
TJ = 25 °C
Typ
Values
10
1
0.15
45
65
1.3
0.85
200
2
200
500
1
1100
Unit
mA
V
V
mA
mA
V
V
mΩ
µA
V/µs
A/ms
V
DocID9469 Rev 4
3/17
17