datasheetbank_Logo
búsqueda de Hoja de datos y gratuito Fichas de descarga

MGFW152412-G Ver la hoja de datos (PDF) - Unspecified

Número de pieza
componentes Descripción
Lista de partido
MGFW152412-G
ETC
Unspecified ETC
MGFW152412-G Datasheet PDF : 12 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
DC-DC Converters PCB Mount Type
Ordering information
MGFW10
MGF W 10 24 12 -O
1
2
3
4
5
6
1Series name
R
2Dual output
3Output wattage
4Input voltage
5Output voltage
6 Optional
Y2 : Output voltage
adjustable (+10%, -5%)
MODEL
MAX OUTPUT WATTAGE[W]
DC OUTPUT
VOLTAGE[V]
CURRENT[A]
MGFW102412
10.08
*1 ±12 or +24
0.42
MGFW102415
10.20
±15 or +30
0.34
MGFW104812
10.08
±12 or +24
0.42
MGFW104815
10.20
±15 or +30
0.34
SPECIFICATIONS
MODEL
MGFW102412
MGFW102415
MGFW104812
MGFW104815
INPUT
VOLTAGE[V]
CURRENT[A]
DC9 - 36 (Surge voltage 50V,100ms max)
DC18 - 76 (Surge voltage 100V,100ms max)
(Refer to the instruction manual for input voltage derating.) (Refer to the instruction manual for input voltage derating.)
*2 0.49typ
0.49typ
0.25typ
0.25typ
EFFICIENCY[%]
*2 87typ
87typ
87typ
88typ
VOLTAGE[V]
±12 (+24)
±15 (+30)
±12 (+24)
±15 (+30)
CURRENT[A]
0.42
0.34
0.42
0.34
LINE REGULATION[mV]
60max
75max
60max
75max
LOAD REGULATION[mV]
*3 480max
*4 600max
600max
750max
480max
600max
600max
750max
OUTPUT
RIPPLE[mVp-p]
Po=30% - 120max
*5 Po=0 - 30% 360max
RIPPLE NOISE[mVp-p] Po=30% - 200max
*5 Po=0 - 30% 500max
120max
360max
200max
500max
120max
360max
200max
500max
120max
360max
200max
500max
TEMPERATURE
REGULATION[mV]
-20 to +50C 150max
-40 to +50C 240max
180max
290max
150max
240max
180max
290max
DRIFT[mV]
*6 48max
60max
48max
60max
START-UP TIME[ms]
30max (Minimum input, Io=100%)
OUTPUT VOLTAGE SETTING[V] 11.64 - 12.36
14.55 - 15.45
11.64 - 12.36
14.55 - 15.45
PROTECTION OVERCURRENT PROTECTION Works over 105% of rating and recovers automatically
CIRCUIT AND
OTHERS
REMOTE ON/OFF
Provided (Negative logic L : ON, H : OFF)
ISOLATION INPUT-OUTPUT
DC1,500V or AC1,000V 1minute, Cutoff current=10mA, DC500V 1,000MW min (20±15C)
OPERATING TEMP.,HUMID.AND ALTITUDE -40 to +85C, 20 to 95%RH (Non condensing) (Required derating), 5,000m (16,400feet) max
STORAGE TEMP.,HUMID.AND ALTITUDE -40 to +100C, 20 to 95%RH (Non condensing), 9,000m (30,000feet) max
ENVIRONMENT
VIBRATION
10 - 55Hz 98.0m/s2 (10G), 3minute period, 60minutes each along X, Y and Z axis
IMPACT
490.3m/s2 (50G) 11ms, once each along X, Y and Z axis
SAFETY AGENCY APPROVALS
UL60950-1, C-UL, EN60950-1
OTHERS
CASE SIZE/WEIGHT
COOLING METHOD
22.0×12.0×9.5mm [0.87×0.48×0.38 inches] (WXHXD) / 7g max
Convection/Forced air
*1 Single output +24V, +30V with no use of COM.
*2 Rated input 5V, 12V, 24V or 48V DC Io=100%
*3 Symmetrical loading from 20% to 100%.
*4 Symmetrical loading from 0% to 100%.
*5 Ripple and Ripple Noise is measured by using test board with ceramic capacitor 1 F at 50mm from output pins. Po:Output wattage.
*6 Drift is the DC output accuracy for eight hours period after a half-hour warm-up at 25C.
* Parallel operation with other model is not possible.
MG-44

Share Link: 

datasheetbank.com [ Privacy Policy ] [ Request Datasheet ] [ Contact Us ]