datasheetbank_Logo
búsqueda de Hoja de datos y gratuito Fichas de descarga

STK392-010 Ver la hoja de datos (PDF) - SANYO -> Panasonic

Número de pieza
componentes Descripción
Lista de partido
STK392-010 Datasheet PDF : 4 Pages
1 2 3 4
Ordering number:ENN5170
Thick Film Hybrid IC
STK392-110
3-Channel Convergence Correction Circuit
(IC max = 3A)
Overview
The STK392-110 is a convergence correction circuit IC for
video projectors. It incorporates three output amplifiers in
a single package, making possible the construction of CRT
horizontal and vertical convergence correction output cir-
cuits for each of the RGB colors using ust two hybrid ICs.
The output circuit use a class-B configuration, in compari-
son with the STK392-010, realizing a more compact pack-
age and lower cost.
Applications
• Video projectors
Features
• 3 output amplifier circuits in a single package
• High maximum supply voltage (VCC max = ±38V)
• Low thermal resistance (θj-c=3.0°C/W)
• High temperature stability (TC max=125°C)
• Separate predriver and output stage supplies
• Output stage supply switching for high-performance
designs
• Low inrush current when power is applied
Package Dimensions
unit:mm
4083
[STK392-110]
64.0
55.6
3.6
1
(6.21)
2.54
17×2.54=43.18
18
0.5
8.5
2.9
0.4
5.5
SANYO : SIP18
Series Organization
The following devices form a series with varying output capacity and application grade. Some of the devices below are
under development, so contact your nearest sales representative for details.
Type No.
STK392-110
STK392-010
STK392-020
STK392-040
STK392-210
STK392-220
VCC max
±38V
±38V
±44V
±50V
±65V
±75V
Maximum ratings
IC max
3A
5A
6A
7A
8A
10A
θj-c
3.0˚C/W
2.6˚C/W
2.1˚C/W
1.8˚C/W
1.5˚C/W
1.3˚C/W
Maximum horizontal frequency
fH max
15kHz
15kHz
35kHz
100kHz
130kHz
160kHz
Application grade
General projection TVs
General projection TVs
HD, VGA
XGA, CAD, CAM
CAD, CAM
CAD, CAM
Any and all SANYO products described or contained herein do not have specifications that can handle
applications that require extremely high levels of reliability, such as life-support systems, aircraft’s
control systems, or other applications whose failure can be reasonably expected to result in serious
physical and/or material damage. Consult with your SANYO representative nearest you before using
any SANYO products described or contained herein in such applications.
SANYO assumes no responsibility for equipment failures that result from using products at values that
exceed, even momentarily, rated values (such as maximum ratings, operating condition ranges,or other
parameters) listed in products specifications of any and all SANYO products described or contained
herein.
SANYO Electric Co.,Ltd. Semiconductor Company
TOKYO OFFICE Tokyo Bldg., 1-10, 1 Chome, Ueno, Taito-ku, TOKYO, 110-8534 JAPAN
93099TH (KT)/80995HA (ID) No.5170–1/4