IRS212(7, 71, 8, 81)(S)PbF
Dynamic Electrical Characteristics
VBIAS (VCC, VBS) = 15 V, CL = 1000 pF and TA = 25 °C unless otherwise specified. The dynamic electrical characteristics
are measured using the test circuit shown in Fig. 3.
Symbol
Definition
Min. Typ. Max. Units Test Conditions
ton
Turn-on propagation delay
— 150 200
VS = 0 V
toff
Turn-off propagation delay
— 150 200
VS = 600 V
tr
Turn-on rise time
—
80 130
tf
Turn-off fall time
—
40 65
ns
tbl
Start-up blanking time
550 750 950
tcs
CS shutdown propagation delay
—
65 360
tflt
CS to FAULT pull-up propagation delay
Static Electrical Characteristics
— 270 510
VBIAS (VCC, VBS) = 15 V and TA = 25 °C unless otherwise specified. The VIN, VTH, and IIN parameters are referenced to
COM. The VO and IO parameters are referenced to VS.
Symbol
Definition
Min. Typ. Max. Units Test Conditions
Logic “1” input voltage
(IRS2127/IRS21271)
VIH
Logic “0” input voltage
(IRS2128/IRS21281)
2.5
——
V
VIL
Logic “0” input voltage
(IRS2127/IRS21271)
Logic “1” input voltage
(IRS2128/IRS21281)
— — 0.8
VCC = 10 V to 20 V
VCSTH+
VOH
VOL
ILK
IQBS
IQCC
IIN+
IIN-
ICS+
ICS-
VBSUV+
VBSUV-
IO+
IO-
CS input positive
(IRS2127/IRS2128)
180
going threshold
(IRS21271/IRS21281)
1.5
High level output voltage, VBIAS - VO
—
Low level output voltage, VO
—
Offset supply leakage current
—
Quiescent VBS supply current
—
Quiescent VCC supply current
—
Logic “1” input bias current
—
Logic “0” input bias current
—
“High” CS bias current
—
“High” CS bias current
—
VBS supply undervoltage
positive going threshold
(IRS2127/IRS2128)
8.8
(IRS21271/IRS21281) 6.3
VBS supply undervoltage (IRS2127/IRS2128)
7.5
negative going threshold (IRS21271/IRS21281) 6.0
Output high short circuit pulsed current
200
Output low short circuit pulsed current
420
250 320
1.8 2.1
0.05 0.2
0.02 0.1
— 50
300 800
60 120
7.0 15
— 5.0
— 5.0
— 5.0
10.3 11.8
7.2 8.2
9.0 10.6
6.8 7.7
290 —
600 —
mV
V
IO = 2 mA
VB = VS = 600 V
VIN = 0 V or 5 V
µA
VIN = 5 V
VIN = 0 V
VCS = 3 V
VCS = 0 V
V
VO = 0 V, VIN = 5 V
mA
PW ≤ 10 µs
VO = 15 V, VIN = 0 V
PW ≤ 10 µs
Ron,FLT FAULT - low on resistance
— 125 —
Ω
www.irf.com