datasheetbank_Logo
búsqueda de Hoja de datos y gratuito Fichas de descarga

LBA110L Ver la hoja de datos (PDF) - IXYS CORPORATION

Número de pieza
componentes Descripción
Lista de partido
LBA110L Datasheet PDF : 9 Pages
1 2 3 4 5 6 7 8 9
INTEGRATED CIRCUITS DIVISION
Absolute Maximum Ratings @ 25°C
Parameter
Ratings Units
Blocking Voltage
Reverse Input Voltage
350
VP
5
V
Input Control Current
50
mA
Peak (10ms)
1
A
Input Power Dissipation 1
150
mW
Total Power Dissipation 2
800
mW
Isolation Voltage, Input to Output 3750
Vrms
Operational Temperature
-40 to +85 °C
Storage Temperature
-40 to +125 °C
1 Derate linearly 1.33 mW / °C
2 Derate linearly 6.67 mW / °C
LBA110L
Absolute Maximum Ratings are stress ratings. Stresses in
excess of these ratings can cause permanent damage to
the device. Functional operation of the device at conditions
beyond those indicated in the operational sections of this
data sheet is not implied.
Electrical Characteristics @ 25°C
Parameter
Conditions
Symbol
Min
Typ
Max
Output Characteristics
Load Current
Continuous 1
Peak (1-Form-B Relay Only)
Load Current Limiting (1-Form-A Relay Only)
On-Resistance 2
Off-State Leakage Current
Switching Speeds
-
t =10ms
-
IL=120mA
VL=350VP
IL
-
-
±120
ILPK
-
-
±350
ICL
±130
±170
±210
RON
-
23
35
ILEAK
-
-
1
Turn-On
Turn-Off
Output Capacitance
Input Characteristics
IF=5mA, VL=10V
ton
toff
VL=50V, f=1MHz
COUT
-
-
3
-
-
3
-
25
-
Input Control Current to Activate
Input Control Current to Deactivate
IL=120mA
IF
-
-
5
-
-
0.4
0.7
-
Input Voltage Drop
Reverse Input Current
Common Characteristics
IF=5mA
VR=5V
VF
0.9
1.2
1.4
IR
-
-
10
Input to Output Capacitance
-
CI/O
-
3
-
1 If both poles operate, then the load current must be derated so as not to exceed the package power dissipation value.
2 Measurement taken within one (1) second of on-time.
Units
mArms / mADC
mAP
mA
A
ms
pF
mA
mA
V
A
pF
2
www.ixysic.com
R06

Share Link: 