±15kV ESD-Protected, +5V, 1µA, Single RS-232
Transceiver with AutoShutdown
+5V
ISHDN
CBYPASS
0.1µF
C1
0.1µF
C2
0.1µF
2 C1+
4 C1-
5 C2+
6 C2-
11 TIN
15
VCC
MAX221E
9 ROUT
3
V+
C3
0.1µF
7
V-
TOUT 13
RIN 8
5k
C4
0.1µF
3k
1 EN
12 FORCEON
INVALID 10
GND
14
FORCEOFF 16
TO POWER-
MANAGEMENT
UNIT
Figure 1. Shutdown Current Test Circuit
_______________Detailed Description
Dual Charge-Pump Voltage Converter
The MAX221E’s internal power supply consists of a
dual charge pump that provides a positive output volt-
age (doubling charge pump) and negative output volt-
age (inverting charge pump) from a single +5V supply.
The charge pumps operate in continuous mode. Each
charge pump requires a flying capacitor (C1, C2) and a
reservoir capacitor (C3, C4) to generate the V+ and V-
supplies.
RS-232 Transmitter
The transmitter is an inverting level translator that con-
verts CMOS-logic levels to 5.0V EIA/TIA-232 levels. It
guarantees a 250kbps data rate with worst-case loads
of 3kin parallel with 1000pF.
When FORCEOFF is driven to ground, or when the
AutoShutdown circuitry senses invalid voltage levels on
the receiver input, the transmitter is disabled and the
output is forced into a high-impedance state. The trans-
mitter input does not have a pull-up resistor.
RS-232 Receiver
The MAX221E’s receiver converts RS-232 signals to
CMOS-logic output levels. The receiver has an inverting
three-state output and can be active or inactive. In
shutdown (FORCEOFF = low) or in AutoShutdown, the
receiver is active (Table 1). Drive EN high to place the
receiver in a high-impedance state. The receiver is
high-impedance when the MAX221E is in shutdown
(FORCEOFF = low).
The MAX221E’s INVALID output is pulled low when
there is no valid RS-232 signal level detected on the
receiver input. INVALID is functional in any mode
(Figures 2 and 3).
AutoShutdown
The MAX221E achieves 1µA supply current with
Maxim’s AutoShutdown feature, which operates when
FORCEON is low and FORCEOFF is high. When the
device senses no valid signal levels on the receiver
input for 30µs, the on-board charge pump and driver
are shut off, reducing supply current to 1µA. This
occurs if the RS-232 cable is disconnected or the con-
nected peripheral transmitter is turned off. The
MAX221E turns on again when a valid level is applied
to the RS-232 receiver input. As a result, the system
saves power without changes to the existing BIOS or
operating system.
Table 1 and Figure 2c summarize the MAX221E operat-
ing modes. FORCEON and FORCEOFF override
AutoShutdown. When neither control is asserted, the
device selects between these states automatically,
based on the receiver input level. Figures 2a, 2b, and
3a depict valid and invalid RS-232 receiver levels.
Figure 3 shows the input levels and timing diagram for
AutoShutdown operation.
A device or another system with AutoShutdown con-
nected to the MAX221E may need time to wake up.
Figure 4 shows a circuit that forces the transmitter on
for 100ms, allowing enough time for the other system to
realize that the MAX221E is awake. If the other system
transmits valid RS-232 signals within that time, the
RS-232 ports on both systems remain enabled.
When shut down, the device’s charge pumps turn off,
V+ is pulled to VCC, V- is pulled to ground, and the
transmitter output is high impedance. The time required
to exit shutdown is typically 100µs (Figure 3b).
_______________________________________________________________________________________ 5