DC and AC Parameters
STM1061
Table 5. DC and AC Characteristics
Sym.
Description
Test Condition (1)
Min
Typ
Max
VCC Operating Voltage
ICC VCC Supply Current
IOUT
Output Current, N-channel
(VDS = 0.5V),
Reset asserted
Voltage Thresholds
Detect Voltage (2)
VTH– (see Table 9 on page 21 for
detailed listing)
VCC = 3.0V, No Load
VCC = 5.5V, No Load
VCC = 1.0V
VCC = 2.0V
VCC = 3.0V
VCC = 4.0V
VCC = 5.0V
0.7
1.0
3.0
5.0
6.0
7.0
VTH– – 2%
VTH+ Release Voltage
VHYST Threshold Hysteresis
tPD VCC to OUT Detect Delay
VCC falling from (VTH–
+ 100mV) to (VTH– –
100mV)
at 10mV/µs
VCC rising from (VTH+
tPR
VCC to OUT Release Delay
– 100mV) to (VTH+ +
100mV)
at 10mV/µs
Threshold Temperature
Coefficient
0.02VTH–
0.9
1.1
1.7
14
22
26
30
VTH–
VTH– +
VHYST
0.05VTH–
25
30
±100
6.0
3.0
3.6
VTH– + 2%
0.08VTH–
200
1. Valid for Ambient Operating Temperature: TA = 25°C.
2. Other VTH- threshold are offered. Minimum order quantities may apply. Contact local sales office for availability.
Unit
V
µA
µA
mA
mA
mA
mA
mA
V
V
V
µs
µs
ppm/oC
16/23