datasheetbank_Logo
búsqueda de Hoja de datos y gratuito Fichas de descarga

IDT54841AD Ver la hoja de datos (PDF) - Integrated Device Technology

Número de pieza
componentes Descripción
Lista de partido
IDT54841AD
IDT
Integrated Device Technology IDT
IDT54841AD Datasheet PDF : 7 Pages
1 2 3 4 5 6 7
IDT54/74FCT841A/B/C
HIGH-PERFORMANCE CMOS BUS INTERFACE LATCHES
MILITARY AND COMMERCIAL TEMPERATURE RANGES
ABSOLUTE MAXIMUM RATINGS(1)
Symbol
Rating
Commercial
VTERM(2) Terminal Voltage
with Respect to
GND
–0.5 to +7.0
VTERM(3) Terminal Voltage
with Respect to
GND
–0.5 to VCC
TA
Operating
0 to +70
Temperature
TBIAS Temperature
–55 to +125
Under Bias
TSTG Storage
–55 to +125
Temperature
PT
Power Dissipation
0.5
Military Unit
–0.5 to +7.0 V
–0.5 to VCC V
–55 to +125 °C
–65 to +135 °C
–65 to +150 °C
0.5
W
I OUT
DC Output
120
120
mA
Current
NOTE:
2607 tbl 03
1. Stresses greater than those listed under ABSOLUTE MAXIMUM
RATINGS may cause permanent damage to the device. This is a stress
rating only and functional operation of the device at these or any other
conditions above those indicated in the operational sections of this
specification is not implied. Exposure to absolute maximum rating
conditions for extended periods may affect reliability. No terminal voltage
may exceed VCC by +0.5V unless otherwise noted.
2. Input and VCC terminals only.
3. Outputs and I/O terminals only.
CAPACITANCE (TA = +25°C, f = 1.0MHz)
Symbol Parameter (1) Conditions Typ. Max. Unit
CIN
Input
Capacitance
VIN = 0V
6 10 pF
COUT
Output
Capacitance
VOUT = 0V
8 12 pF
NOTE:
2607 tbl 04
1. This parameter is measured at characterization but not tested.
DC ELECTRICAL CHARACTERISTICS OVER OPERATING RANGE
Following Conditions Apply Unless Otherwise Specified: VLC = 0.2V; VHC = VCC – 0.2V
Commercial: TA = 0°C to +70°C, VCC = 5.0V ± 5%; Military: TA = –55°C to +125°C, VCC = 5.0V ± 10%
Symbol
VIH
Parameter
Input HIGH Level
Test Conditions(1)
Guaranteed Logic HIGH Level
Min. Typ.(2) Max. Unit
2.0
V
VIL
Input LOW Level
Guaranteed Logic LOW Level
— 0.8
V
II H
Input HIGH Current
II L
Input LOW Current
VCC = Max.
VI = VCC
VI = 2.7V
VI = 0.5V
5
µA
5(4)
— –5(4)
VI = GND
–5
IOZH
Off State (High Impedance)
Output Current
IOZL
VCC = Max.
VO = VCC
VO = 2.7V
VO = 0.5V
10
µA
— 10(4)
— –10(4)
VO = GND
— –10
VIK
Clamp Diode Voltage
IOS
Short Circuit Current
VCC = Min., IN = –18mA
VCC = Max.(3), VO = GND
— –0.7 –1.2 V
–75 –120 — mA
VOH
Output HIGH Voltage
VCC = 3V, VIN = VLC or VHC, IOH = –32µA
VHC VCC
V
VCC = Min.
IOH = –300µA
VHC VCC
VIN = VIH or VIL
IOH = –15mA MIL.
2.4 4.3 —
IOH = –24mA COM'L. 2.4 4.3
VOL
Output LOW Voltage
VCC = 3V, VIN = VLC or VHC, IOL = 300µA
VCC = Min.
IOL = 300µA
— GND VLC
V
— GND VLC(4)
VIN = VIH or VIL
IOL = 32mA MIL.
— 0.3 0.5
IOL = 48mA COM'L.
— 0.3 0.5
NOTES:
1. For conditions shown as Max. or Min., use appropriate value specified under Electrical Characteristics for the applicable device type.
2. Typical values are at VCC = 5.0V, +25°C ambient and maximum loading.
3. Not more than one output should be shorted at one time. Duration of the short circuit test should not exceed one second.
4. This parameter is guaranteed but not tested.
2607 tbl 05
7.22
3

Share Link: 

datasheetbank.com [ Privacy Policy ] [ Request Datasheet ] [ Contact Us ]