datasheetbank_Logo
búsqueda de Hoja de datos y gratuito Fichas de descarga

MTL001 Ver la hoja de datos (PDF) - Myson Century Inc

Número de pieza
componentes Descripción
Lista de partido
MTL001
Myson
Myson Century Inc Myson
MTL001 Datasheet PDF : 64 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
MYSON
TECHNOLOGY
MTL001
(Rev. 0.95)
¨ V/H SYNC Frequency Counter
MTL001 measures VSYNC/HSYNC frequency counted in the proper clock and save the information in
register. Users can read the figure and calculate VSYNC/HSYNC frequency using the following formulae:
fvsync = fosc / Nvsync 51/256
fhsync = fosc / Nhsync 58
Where
fvsync
fhsync
fosc
Nvsync
Nhsync
: VSYNC frequency
: HSYNC frequency
: oscillator clock with 14.31818 MHz
: counted number of VSYNC
: counted number of HSYNC
¨ V/H SYNC Presence Check
This function checks the input VSYNC, where Vpre flag is set when VSYNC is over 40Hz or cleared when
VSYNC is under 10Hz and the input is HSYNC, where Hpre flag is set when HSYNC is over 10KHz or
cleared when HSYNC is under 10Hz.
¨ V/H Polarity Detect
This function detects the input VSYNC/HSYNC high and low pulse duty cycle. If the high pulse duration is
longer than that of low pulse, the negative polarity is asserted; otherwise, positive polarity is asserted.
¨ Composite SYNC separation/insertion
MTL001 continuously monitors the input HSYNC. If the input VSYNC can be extracted from it, a CVpre flag is
set. MTL001 can insert HSYNC pulse during Composite VSYNC’s active time and the insertion frequency
can adapt to original HSYNC’s.
3.1.7 Auto Tune
Auto Tune function consists of Auto Position that automatically centering the screen and Auto Calibration
which contains Phase Calibration, Histogram, Min/Max Value, and Pixel Grab described as below. With this
auto adjustment support it is possible to measure the correct phase, frequency, gain, and offset of ADC. The
horizontal and vertical back porches of input image and the horizontal and vertical active regions can also be
measured. Firmware can adjust input image registers automatically by reading Auto Tune’s registers in single
or burst mode.
¨ Auto Position
MTL001 provides Horizontal/Vertical back porch and active region values. Users can use these values to set
input sample registers to aid in centering the screen automatically.
¨ Phase Calibration
MTL001 provides Auto Calibration registers to measure the quality of current ADC’s phase and frequency.
The biggest Auto Calibration registers value means the right value of ADC’s phase and frequency. MTL001
has two kinds of algorithms to calculate Auto Calibration’s value. One is the traditional Difference method, the
other is MYSON’s proprietary method; the latter one is recommended for a better performance.
¨ Histogram
Histogram means the total number of input pixels below/above one threshold value, for individual R/G/B
colors. This advanced function helps the firmware to analyze ADC performance. Usually the firmware can
use this information to measure ADC’s noise margin, and adjust its offset and gain, or even aid in the mode
detection.
¨ Min/Max Value
Min/Max value means minimum or maximum pixel value within the specified input active image region for
each RGB channel. This information is usually used to adjust ADC’s offset and gain.
¨ Pixel Grab
Pixel Grab means users can grab a single input pixel at any one point. The position of the point can be
programmed by users. This is another traditional method to measure ADC’s phase and frequency.
Revision 0.95
-8-
2000/06/14

Share Link: 