Data Sheet
AC Electrical Characteristics- Clock Timing (Figures 9 and 10)
Characteristics
Sym. Min. Typ.Max. Units
Test Conditions
1
Clock Period*
tCLK
220
244 300
ns
2 I Clock Width High
3 N Clock Width Low
4
P
U
Clock Transition Time
5 T Frame Pulse Setup Time
6 S Frame Pulse Hold Time
tCH
85
122 150 ns
tCL
85
122 150 ns
tCTT
10
ns
tFPS
10
190 ns
tFPH
10
190 ns
7
Frame Pulse Width
tFPW
244
ns
† Timing is over recommended temperature & power supply voltages.
‡ Typical figures are at 25°C and are for design aid only: not guaranteed and not subject to production testing.
* Contents of Connection Memory are not lost if the clock stops, however, ST-BUS outputs go into the high impedance state.
NB: Frame Pulse is repeated every 512 cycles of C4i.
C4i
F0i
BIT
CELLS
Channel 31
Bit o
Channel 0
Bit 7
Figure 9 - Frame Alignment