datasheetbank_Logo
búsqueda de Hoja de datos y gratuito Fichas de descarga

MAP110-4002GC Ver la hoja de datos (PDF) - Bel Fuse Inc.

Número de pieza
componentes Descripción
Lista de partido
MAP110-4002GC
BEL
Bel Fuse Inc. BEL
MAP110-4002GC Datasheet PDF : 6 Pages
1 2 3 4 5 6
MAP110 Series
3
MAP110-4200G
MAP110-4300* 5,6
MAP110-4305* 5,6
-15V
+15V
+12V
+24V
-12V
+5V
+3.3V
+5V
-12V
+12V
+3.3V
+5V
-5V
+12V
Fixed
Fixed
11.55V to
12.45V
Fixed
Fixed
Fixed
3.2V to 3.4V
Fixed
Fixed
Fixed
3.2V to 3.4V
Fixed
Fixed
Fixed
1A/1.5A PK
1A/1.5A PK
5A/9A PK
4A/4.5A PK
1A/1.5A PK
2A/2.5A PK
12A/20A PK
5A/12A PK
1A/1.5A PK
1A/1.5A PK
12A/15A PK
5A/12A PK
1A/1.5A PK
1A/1.5A PK
1A/1.5A PK
1A/1.5A PK
5A/9A PK
4A/4.5A PK
1A/1.5A PK
2A/2.5A PK
15A/20A PK
8A/12A PK
1A/1.5A PK
1A/1.5A PK
15A/20A PK
8A/12A PK
1A/1.5A PK
1A/1.5A PK
0.1%
0.1%
0.2%
0.2%
0.2%
0.2%
0.3%
0.2%
0.1%
0.1%
0.3%
0.2%
0.1%
0.1%
1%
1%
0.5%
1%
1%
1.5%
0.7%
1%
1%
1%
0.7%
1%
1%
1%
1%
1%
0.5%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
-14.4V to -15.6V
14.4V to 15.6V
11.96V to 12.03V
23.94V to 24.06V
-11.4V to -12.6V
4.75V to 5.25V
3.29V to 3.31V
4.98V to 5.02V
-11.4V to -12.6V
11.4V to 12.6V
3.29V to 3.31V
4.98V to 5.02V
-4.75V to -5.25V
11.4V to 12.6V
1 With minimum 200LFM forced-air cooling.
2 Maximum peak to peak noise expressed as a percentage of output voltage, 20 MHz bandwidth.
3 MAP110-1024 output currents are expressed as 24V/28V operation.
4 Peak loads up to 110 watts for 60 seconds or less are acceptable, (10% duty cycle max.). Peak power must not exceed 110 watts.
5 Sum of the output currents of V1 + V2 may not exceed 15 A continuous, 22 A peak.
6 Maximum operating ambient temperature of 40°C
7 Non-G models use lead solder exemption and are not recommended for new designs.
* O * Obsolete
MODEL/OUTPUT OPTION
Convection Continuous /
Peak
Forced Air 200 LMF
MULTIPLE OUTPUT
BOARD ONLY
80W/110W
110W
SINGLE OUTPUT
BOARD ONLY
90W/120W
120W
MULTIPLE OUTPUT
‘C’-COVER
60W/110W
110W
SINGLE OUTPUT
C’-COVER
65W/120W
120W
PARAMETER
Input Voltage - AC
Input Frequency
Brown Out Protection
Hold-up Time
Input Current
Input Protection
Inrush Surge Current
Operating Frequency
CONDITIONS / DESCRIPTION
Continuous input range
AC input
Lowest AC input voltage when regulation is maintained with full
rated loads.
Nominal AC input voltage (110 VAC)
50% load:
Full rated load:
85 VAC (110W load)
110VAC (110W load)
Non-user serviceable internally located AC input line fuse.
Internally limited by thermistor. Vin = 264 VAC (one cycle). 25 °C.
Switching frequency of main transformer, (fixed frequency).
MIN
85
47
85
40
20
20
NOM
MAX
264
63
UNITS
VAC
Hz
VAC
mS
3.5
2.8
ARMS
41
APK
25
kHz
Asia-Pacific
+86 755 298 85888
Europe, Middle East
+353 61 225 977
© 2016 Bel Power Solutions & Protection
North America
+1 408 785 5200
BCD.00566_AB