datasheetbank_Logo
búsqueda de Hoja de datos y gratuito Fichas de descarga

MAP110-4002GT Ver la hoja de datos (PDF) - Bel Fuse Inc.

Número de pieza
componentes Descripción
Lista de partido
MAP110-4002GT
BEL
Bel Fuse Inc. BEL
MAP110-4002GT Datasheet PDF : 6 Pages
1 2 3 4 5 6
4
MAP110 Series
PARAMETER
Efficiency
Minimum Loads
Ripple and Noise
Output Power
Overshoot / Undershoot
Regulation
Transient Response
Turn-on Delay
Turn-on Rise Time
CONDITIONS / DESCRIPTION
Full load @ 230 VAC (Varies with distribution of loads among
outputs.)
Single output models
Multiple output models, V1 + V28
Full Load, 20 MHz Bandwidth.
Multiple output units with convection cooling.
Multiple output units with 200 LFM forced air cooling.
Output voltage overshoot/undershoot at turn-on.
Varies by output, regulation includes: line changes from 90-132 VAC
or 175-264, changes in load starting at 20% load and changing to
100% load.
Recovery time, to within 1% of initial set point due to a 50-100%
load change, 4% max. deviation. (Main output only on multiple
output units).
Time required for initial output voltage stabilization.
Time required for output voltage to rise from 10% to 90%.
MIN
NOM
MAX UNITS
70% typical
0
1
Amps
See Model Selection Chart
5
5
80
110
Watts
1
%
See Model Selection Chart
500
µS
1
Sec
20
mS
8 Minimum load is required only to meet the regulation limits of V3 and V4. If V3 and V4 are unused, no minimum load is necessary.
PARAMETER
Overvoltage Protection
Overload Protection
Remote Sense
Input Power Fail Warning
Over temperature Protection
CONDITIONS / DESCRIPTION
MAP110-1005G
MAP110-1012G
Provided on single output models and the
main output of multiple output models.
MAP110-1024G
MAP110-4200G
MAP110-4300G
All other models
Fully protected against output overload and short circuit.
Automatic recovery upon removal of overload condition.
Voltage drop compensated for at the load.
Option, TTL compatible logic signal. Time before regulation dropout
due to loss of input power at 110 VAC. Active low.
Option, system shutdown due to excessive internal temperature.
MIN
6.10
17.3
32.2
13.8
3.7
5.75
3
NOM
150
5
MAX
7.20
20.2
37.8
16.2
4.35
6.75
200
250
UNITS
V
%
mV
mS
PARAMETER
Agency Approvals
Dielectric Withstand Voltage
Electromagnetic Interference,
Conducted
Input Transient Protection
CONDITIONS / DESCRIPTION
Approved to the latest edition of the following standards;
UL/CSA60950-1 2nd, IEC60950-1 2nd and EN60950-1 2nd.
Input to Chassis
Input to Output (tested by manufacturer only)
FCC CFR title 47 Part 15 Sub-Part B - conducted & radiated
EN55022 / CISPR 22 conducted
EN55022 / CISPR 22 radiated9
EN61000-4-5 Level 3
Insulation Resistance
Input to output
Leakage Current
Per EN60950, 264 VAC
9 The following units meet Class B: MAP110-1005, MAP110-4000/4011/4015/4200/4300.
MIN
NOM MAX UNITS
2121
4242
B
B
A
2
VDC
Class
kV
10
MΩ
750
μA