Dual SPM/Security Detector/Generator
15 of 23
CMX641A Advance Information
5.3 Channel 1 and Channel 2 Output Format
Figure 5 illustrates the two output formats: Tone Follower mode and Packet mode.
SIGNAL INPUT
TONE
NOTONE
CH1 and CH2 OUTPUTS
TONE FOLLOWER OUTPUT
PACKET MODE OUTPUT
SIGNAL INPUT ......
RESPONSE
DELAY
TONE FOLLOWER OUTPUT ......
PACKET MODE OUTPUT ......
DERESPONSE
DELAY
Figure 5: Tone Follower and Packet Mode Outputs
5.4 Setting Level Sensitivity via the Input Serial Data Word
The serial data word input is used to set the device sensitivity in the Controlled Sensitivity mode of the Fixed
Bandwidth Operating state and in the Enhanced Features Operating state.
In Controlled Sensitivity mode of the Fixed Bandwidth Operating state, the CMX641A operates identically to
the FX641 and MX641. The input word is 6 bits and Table 3 lists the device sensitivities vs input codes.
In the Enhanced Features Operating State, channel 1’s sensitivity is controlled by applying the codes in Table
3 to bits D15-D11. Channel 2’s sensitivity is controlled by applying these codes to bits D8-D4.
Example: Suppose the CMX641A is required to work in a system in which 16kHz signals, at or above –
22dB(ref) must be detected and signals at or below –27dB(ref) must not be detected. Reference to Table 3
shows that bandpass filter gain settings of 6dB or 7dB will meet this level specification.
Thus in Fixed Bandwidth Operating State and Controlled Sensitivity Mode:
Inputting D5-D0 = ’001100’ or ‘001110’ (See Table 3) will set both channels to meet this specification.
Selecting ‘001100’ makes both channels’ minimum ‘Will Detect’ level –22.9dB(ref) and its maximum ‘Will Not
Detect’ level –25.5dB(ref). This means that the detection threshold of any device will lie between these two
levels.
In Enhanced Features Operating State Channel 2:
Inputting D15-D11 = ‘00110’ or ‘00111’ (See Table 3 and Table 4) and D1-D0 = ‘00’ (See Table 7) will program
channel 2 to meet this level specification. Selecting ‘00111’ makes the channel 2 minimum ‘Will Detect’ level
–23.9dB(ref) and its maximum ‘Will Not Detect’ level –26.5dB(ref). This means that Channel 2’s detection
threshold will lie between these two levels.
In Enhanced Features Operating State Channel 1:
Inputting D8-D4 = ‘00110’ or ‘00111’ (See Table 3 and Table 4) and D1-D0 = ‘00’, ‘01’ or ‘10’ (See Table 7) will
program channel 1 to meet this level specification. Selecting ‘00110’ makes the CMX641A minimum ‘Will
Detect’ level –22.9dB(ref) and its maximum ‘Will Not Detect’ level –25.5dB(ref). This means that channel 1’s
detection threshold will lie between these two levels. The two channels may be set to identical detection
thresholds, if desired.
ã2001 MX-COM, Inc.