datasheetbank_Logo
búsqueda de Hoja de datos y gratuito Fichas de descarga

ISL21010 Ver la hoja de datos (PDF) - Renesas Electronics

Número de pieza
componentes Descripción
Lista de partido
ISL21010
Renesas
Renesas Electronics Renesas
ISL21010 Datasheet PDF : 37 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
ISL21010
Electrical Specifications (ISL21010-41, VOUT = 4.096V) VIN = 5.0V, TA = +25°C, IOUT = 0A, unless otherwise
specified. Boldface limits apply across the operating temperature range, -40°C to +125°C.
PARAMETER
SYMBOL
TEST CONDITIONS
MIN
MAX
(Note 8) TYP (Note 8)
UNIT
Output Voltage
VOUT Accuracy at TA = +25°C (Note 7)
Output Voltage Temperature Coefficient (Note 9)
Input Voltage Range
Supply Current
Line Regulation
Load Regulation
Dropout Voltage (Note 10)
Short-Circuit Current
Turn-On Settling Time
Ripple Rejection
VOUT
VOA
TC VOUT
VIN
IIN
VOUT /VIN
VOUT/IOUT
VINDO
ISC
tR
TA = +25°C
TA = -40°C to +125°C
4.2 V < VIN < 5.5V
Sourcing: 0mA IOUT 25mA
Sinking: -1mA IOUT 0mA
IOUT = 10mA
TA = +25°C, VOUT tied to GND
VOUT = ±0.1%, COUT = 1μF
f = 120Hz
4.096
V
-0.2
+0.2
%
15
50 ppm/°C
4.2
5.5
V
48
80
µA
100
µA
106 550
µV/V
50 140 µV/mA
50
µV/mA
60 150
mV
126
mA
300
µs
58
dB
Output Voltage Noise
eN
0.1Hz f 10Hz
112
µVP-P
Broadband Voltage Noise
VN
10Hz f 1kHz
56
µVRMS
Thermal Hysteresis (Note 11)
VOUT/TA
TA = +165°C
100
ppm
Long Term Stability
VOUT/t
1000 hours, TA = +25°C
110
ppm
NOTES:
8. Compliance to datasheet limits is assured by one or more methods: production test, characterization, and/or design.
9. Over the specified temperature range. Temperature coefficient is measured by the box method whereby the change in VOUT is divided by the
temperature range; in this case, -40°C to +125°C = +165°C.
10. Dropout Voltage is the minimum VIN - VOUT differential voltage measured at the point where VOUT drops 1mV from VIN = nominal at TA = +25°C.
11. Thermal Hysteresis is the change of VOUT measured at TA = +25°C after temperature cycling over a specified range, TA. VOUT is read initially at
TA = +25°C for the device under test. The device is temperature cycled and a second VOUT measurement is taken at +25°C. The difference between
the initial VOUT reading and the second VOUT reading is then expressed in ppm. For TA = +165°C, the device under test is cycled from +25°C to
-40°C to +125°C to +25°C.
FN7896 Rev 5.00
Mar 30, 2018
Page 9 of 37