CS5394
ABSOLUTE MAXIMUM RATINGS (AGND, DGND = 0 V, All voltages with respect to ground.)
Parameter
Symbol
Min
Max
Unit
DC Power Supplies
Positive Analog VA
-0.3
Positive Logic VL
-0.3
Positive Digital VD
-0.3
|VA - VD|
-
|VA - VL|
-
|VD - VL|
-
+6.0
V
+6.0
+6.0
0.4
0.4
0.4
Input Current
(Note 5)
Iin
-
±10
mA
Analog Input Voltage
(Note 6) VINA
-0.7
(VA) + 0.7
V
Digital Input Voltage
(Note 6) VIND
-0.7
(VD) + 0.7
V
Ambient Operating Temperature (Power Applied)
TA
-55
+100
°C
Storage Temperature
Tstg
-65
+150
°C
Notes: 5. Any pin except supplies. Transient currents of up to ±100 mA on the analog input pins will not cause
SCR latch-up.
6. The maximum over/under voltage is limited by the input current.
WARNING: Operation at or beyond these limits may result in permanent damage to the device.
Normal operation is not guaranteed at these extremes.
RECOMMENDED OPERATING CONDITIONS
(AGND, DGND = 0 V, All voltages with respect to ground.)
DC Power Supplies
Parameter
Symbol Min
Typ
Max Unit
Positive Analog VA
Positive Logic VL
Positive Digital VD
|VA - VD|
4.75
5.0
5.25
V
4.75
5.0
5.25
4.75
5.0
5.25
-
-
0.4
DS258PP4
5

Share Link: 