datasheetbank_Logo
búsqueda de Hoja de datos y gratuito Fichas de descarga

HI3-DAC80V-5 Ver la hoja de datos (PDF) - Intersil

Número de pieza
componentes Descripción
Lista de partido
HI3-DAC80V-5 Datasheet PDF : 7 Pages
1 2 3 4 5 6 7
HI-DAC80V, HI-DAC85V
Reference Supply
An internal 6.3V reference is provided on board the
HI-DAC80V/HI-DAC85V. The voltage (pin 24) is accurate to
±0.8% and must be connected to the reference input (pin 16)
for specified operation. This reference may be used exter-
nally, provided current drain is limited to 2.5mA. An external
buffer amplifier is recommended if this reference is to be
used to drive other system components. Otherwise, varia-
tions in the load driven by the reference will result in gain
variations of the HI-DAC80V/HI-DAC85V. All gain adjust-
ments should be made under constant load conditions.
Output Voltage Ranges
24
17
-
+
6.3K
16
+VS
12.6k
R1
23
2.8M
CONTROL
AMP
-VS
10kTO
100k
0.01µF
18
5k19
+VS
R2
5k
3.9
M
20
-VS
5k
TO
100k
-
15
+
21
FIGURE 2. HI-DAC80V/HI-DAC85V
TABLE 3. GAIN AND OFFSET CALIBRATIONS
UNIPOLAR CALIBRATION
Step 1:
Offset
Turn all bits OFF (11 . . . 1)
Adjust R2 for 0V out
Step 2:
Gain
Turn all bits ON (00 . . . 0)
Adjust R1 for FS - 1 LSB
That is:
4.9988 for 0 to +5V range
9.9976 for 0 to +10V range
BIPOLAR CALIBRATION
Step 1:
Offset
Turn all bits OFF (11 . . . 1)
Adjust R2 for Negative FS
That is:
-10V for ±10V range
-5V for ±5V range
-2.5V for ±2.5V range
Step 2:
Gain
Turn all bits ON (00 . . . 0)
Adjust R1 for Positive FS - 1 LSB
That is:
+9.9951V for ±10V Range
+4.9976V for ±5V Range
+2.4988V for ±2.5V Range
This Bipolar procedure adjusts the output range end points. The
maximum error at zero (half scale) will not exceed the Linearity
Error. See the “Accuracy” Specifications.
Unipolar
Bipolar
TABLE 2. RANGE CONNECTIONS
RANGE
0 to +5V
0 to +10V
±2.5V
±5V
±10V
PIN 15
18
18
18
18
19
CONNECT
PIN 17
NC
NC
20
20
20
PIN 19
20
NC
20
NC
15
10-1039

Share Link: 