DC ELECTRICAL CHARACTERISTICS 1
( -55°C < TC < +125°C)
SYMBOL
PARAMETER
CONDITION
MIN
VT+ Schmitt Trigger, positive going threshold2 VDD from 2.3 to 3.6
VT -
Schmitt Trigger, negative going threshold2 VDD from 2.3 to 3.6
.3V DD
VH1 Schmitt Trigger range of hysteresis9
VDD from 3.0 to 3.6
0.5
VH 2
Schmitt Trigger range of hysteresis9
VDD from 2.3 to 2.7
0.4
IIN
Input leakage current9
VDD from 2.7 to 3.6
-1
VIN = VDD or VSS
IOZ
Three-state output leakage current9
VDD from 2.7 to 3.6
-1
VIN = VDD or VSS
ICS
Cold sparing input leakage current3,11
VIN = 3.6
-5
VDD = VSS
IWS
Warm sparing input leakage current3,11 VIN = VSS or VDD, VDD1 = 0,
-5
VDD2 = V DD or VDD1 =VDD, VDD2 = 0
IOS1
Short-circuit output current 5, 10
VO = VDD or VSS
-200
VDD from 3.0 to 3.6
IOS2
Short-circuit output current 5, 10
VO = VDD or VSS
-100
VDD from 2.3 to 2.7
VOL1 Low-level output voltage9
IOL= 8mA
IOL= 100µA
VDD = 3.0
VOL2 Low-level output voltage9
VOH1 High-level output voltage9
VOH2 High-level output voltage9
IOL= 8mA
IOL= 100µA
VDD = 2.3
IOH= -8mA
IOH= -100µA
VDD = 3.0
IOH= -8mA
IOH= -100µA
VDD = 2.3
VDD - 0.7
VDD - 0.2
VDD - 0.7
VDD - 0.2
MAX
.7VDD
3
3
5
5
200
100
0.4
0.2
0.4
0.2
UNIT
V
V
V
V
µA
µA
µA
µA
mA
mA
V
V
V
V
5