datasheetbank_Logo
búsqueda de Hoja de datos y gratuito Fichas de descarga

L6376D Ver la hoja de datos (PDF) - STMicroelectronics

Número de pieza
componentes Descripción
Lista de partido
L6376D Datasheet PDF : 18 Pages
First Prev 11 12 13 14 15 16 17 18
Programmable diagnostic delay
L6376
Typical waveforms for short circuit operation are shown in Figure 5.
If both the ON DELAY and the OFF DELAY pins are grounded the non dissipative over
current protection is inhibited and the outputs in short circuit remain on until the thermal
shutdown switch OFF the whole device. In this case the short circuit condition is not
signalled by the DIAG pin (that continues to signal the under voltage and over temperature
conditions).
9
Programmable diagnostic delay
The current limiting circuits can be requested to perform even in absence of a real fault
condition, for a short period, if the load is of capacitive nature or if it is a filament lamp (that
exhibits a very low resistance during the initial heating phase).
To avoid the forwarding of misleading — i.e. short diagnostic pulses in coincidence with the
intervention of the current limiting circuits when operating on capacitive loads — the
activation of the diagnostic can be delayed with respect to the intervention of one of the
current limiting circuits.
This delay can be defined by an external capacitor (CDON) connected between the ON
DELAY pin and ground.
10 Reset input
An external reset input R (pin 18) is provided to simultaneously switch OFF all the outputs:
this signal (active low) is in effect an asynchronous reset that keeps the outputs low
independently from the input signals. For example, this reset input can be used by the CPU
to keep the outputs low after a fault condition (signaled by the DIAG pin).
12/18