A29DL32x Series
Command Definitions
Table 12. A29DL32x Command Definitions
Command
Sequence
(Note 1)
First
Second
Addr Data Addr Data
Bus Cycles (Notes 2–5)
Third
Fourth
Addr Data Addr Data
Fifth
Sixth
Addr Data Addr Data
Read (Note 6)
1 RA RD
Reset (Note 7)
1 XXX F0
Manufacturer ID
Word
555
2AA
(BA)555
4
AA
55
90 (BA)X00 37
Byte
AAA
555
(BA)AAA
Device ID
Word
555
4
AA
Byte
AAA
2AA
555
55
(BA)555
(BA)AAA
90
(BA)X01 (see
(BA)X02 Table5)
Continuation ID
Word 4 555 AA 2AA 55
555
90
X03
7F
Byte
AAA
555
AAA
X06
Sector Protect Verify
(Note 9)
Word
555
2AA
(BA)555
(SA)
4
AA
55
90
00/01
Byte
AAA
555
(BA)AAA
(SA)X04
Command Temporary
Sector Unprotect (Note15)
Word
Byte
3
555
AAA
AA
2AA
555
55
555
AAA
77
Program
Word
555
2AA
555
4
AA
55
A0
PA
PD
Byte
AAA
555
AAA
Unlock Bypass
Word
555
2AA
555
3
AA
55
20
Byte
AAA
555
AAA
Unlock Bypass Program (Note 10) 2 XXX A0 PA PD
Unlock Bypass Reset (Note 11)
2 XXX 90 XXX 00
Chip Erase
Word
555
2AA
6
AA
55
Byte
AAA
555
555
AAA
555
80
AA A
2AA
555
AA
55
10
555
AAA
Sector Erase
Word
555
2AA 55
Byte 6 AAA AA
555
555
AAA
80
555
AAA
2AA
AA
55 SA 30
555
Erase Suspend (Note 12)
1 XXX B0
Erase Resume (Note 13)
1 XXX 30
CFI Query (Note 14)
Word 1 55
98
Byte
AA
Legend:
X = Don't care
RA = Address of the memory location to be read.
RD = Data read from location RA during read operation.
PA = Address of the memory location to be programmed. Addresses latch on the falling edge of the WE or CE pulse,
whichever happens later.
PD = Data to be programmed at location PA. Data latches on the rising edge of WE or CE pulse, whichever happens first.
SA = Address of the sector to be verified (in autoselect mode) or erased. Address bits A20 - A12 select a unique sector.
BA = Address of the bank that is being switched to autoselect mode, is in bypass mode, or is being erased.
Note:
1. See Table 1 for description of bus operations.
2. All values are in hexadecimal.
3. Except for the read cycle and the fourth cycle of the autoselect command sequence, all bus cycles are write cycles.
4. Data bits I/O15-I/O8 are don’t care in command sequences. Except for RD and PD.
5. Unless otherwise noted, address bits A20-A11 are don’t cares.
6. No unlock or command cycles required when bank is reading array data.
7. The Reset command is required to return to reading array data (or to the erase-suspend-read mode if previously in Erase
Suspend) when a bank is in the autoselect mode, or if I/O5 goes high (while the bank is providing status information).
8. The fourth cycle of the autoselect command sequence is a read cycle. The system must provide the bank address to obtain
the manufacture ID, or device ID information. Data bits I/O15-I/O8 are don’t care. See the Autoselect Command Sequence
section for more information.
9. The data is 00h for an unprotected sector/sector block and 01h for a protected sector/sector block.
10. The Unlock Bypass command is required prior to the Unlock Bypass Program Command.
11. The Unlock Bypass Reset command is required to return to reading array data when the bank is in the unlock bypass mode.
12. The system may read and program in non-erasing sectors, or enter the autoselect mode, when in the Erase Suspend mode.
The Erase Suspend command is valid only during a sector erase operation, and require the bank address.
13. The Erase Resume command is valid only during the Erase.
14. Command is valid when device is ready to read array data or when device is in autoselect mode.
15. Once a reset command is applied, software temporary unprotect is exit to return to read array data. But under erase
suspend condition, this command is still effective even a reset command has been applied. The reset command which can
deactivate the software temporary unprotect command is useful only after the erase command is complete.
PRELIMINARY (May, 2005, Version 0.0)
25
AMIC Technology, Corp.

Share Link: 

datasheetbank.com [ Privacy Policy ] [ Request Datasheet ] [ Contact Us ]