datasheetbank_Logo
búsqueda de Hoja de datos y gratuito Fichas de descarga

AD2S105AP Ver la hoja de datos (PDF) - Analog Devices

Número de pieza
componentes Descripción
Lista de partido
AD2S105AP
ADI
Analog Devices ADI
AD2S105AP Datasheet PDF : 12 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
AD2S105
Parameter
Min
Typ
Max
Units Conditions
HOMOPOLAR OUTPUT
HPOP–OUTPUT
VOH
VOL
HPREF–REFERENCE
POWER SUPPLY
VDD
VSS
IDD
ISS
4
0.5
4.75
5
–5.25
–5
4
4
1
5.25
–4.75
10
10
V dc
V dc
V dc
IOH = 0.5 mA
IOL = 0.5 mA
Homopolar Output-Internal
ISOURCE = 25 µA and 20 kto AGND
V dc
V dc
mA Quiescent Current
mA Quiescent Current
NOTES
1Angular accuracy includes offset and gain errors, measured with a stationary digital input and maximum analog frequency inputs.
2The angular error does not include the additional error caused by the phase delay as a function of input frequency. For example, if f INPUT = 600 Hz, the contribution
to the error due to phase delay is: 650 ns × fINPUT × 60 × 360 = 8.4 arc minutes.
3Output subject to input voltage and gain.
Specifications subject to change without notice.
RECOMMENDED OPERATING CONDITIONS
Power Supply Voltage (+VDD, –VSS) . . . . . . . . . ± 5 V dc ± 5%
Analog Input Voltage (PH/IP1, 2, 3, 4) . . . . . . 2 V rms ± 10%
Analog Input Voltage (PH/IPH1, 2, 3) . . . . . . 3 V rms ± 10%
Ambient Operating Temperature Range
Industrial (AP) . . . . . . . . . . . . . . . . . . . . . . . –40°C to +85°C
ABSOLUTE MAXIMUM RATINGS (TA = +25°C)
VDD to AGND . . . . . . . . . . . . . . . . . . . . . . . –0.3 V to +7 V dc
VSS to AGND . . . . . . . . . . . . . . . . . . . . . . . +0.3 V to –7 V dc
AGND to DGND . . . . . . . . . . . . . . . . . . . . . . . . . . . ± 0.3 V dc
Analog Input Voltage to AGND . . . . . . . . . . . . . . . VSS to VDD
Digital Input Voltage to DGND . . . . –0.3 V to VDD + 0.3 V dc
Digital Output Voltage to DGND . . . . . . –0.3 V to VDD + V dc
Analog Output Voltage to AGND
. . . . . . . . . . . . . . . . . . . . . . VSS – 0.3 V to VDD + 0.3 V dc
Analog Output Load Condition (PH/OP1, 4
Sinθ, Cosθ) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 k
Power Dissipation . . . . . . . . . . . . . . . . . . . . . . . . . . . . 140 mW
Operating Temperature
Industrial (AP) . . . . . . . . . . . . . . . . . . . . . . . –40°C to +85°C
Storage Temperature . . . . . . . . . . . . . . . . . –65°C to +150°C
Lead Temperature (Soldering, 10 sec) . . . . . . . . . . . . . +300°C
CAUTION
1. Absolute Maximum Ratings are those values beyond which
damage to the device will occur.
2. Correct polarity voltages must be maintained on the +VDD
and –VSS pins
ORDERING GUIDE
Model
Temperature Range
AD2S105AP –40°C to +85°C
*P = Plastic Leaded Chip Carrier.
Accuracy Option*
30 arc min P-44A
CAUTION
ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily
accumulate on the human body and test equipment and can discharge without detection.
Although the AD2S105 features proprietary ESD protection circuitry, permanent damage may
occur on devices subjected to high energy electrostatic discharges. Therefore, proper ESD
precautions are recommended to avoid performance degradation or loss of functionality.
WARNING!
ESD SENSITIVE DEVICE
REV. 0
–3–

Share Link: 