XE2420 Electrical Specifications
Parameter
VCC
ICC
ICC
Vui
Iui
Ring Voltage Detected
Ring Frequency Detected
Connect Detect Sensitivity
Handset Interrupt Detection
Telephone Loop Current
Line Impedance
Data Transmit level
DTMF Transmit Level
Voh
Vol
Vih
Vil
Min Typ Max Units Comments
4.75
5.25 Volts
60
66
72
ma On Line
25
ma idle
4.75
5.25 Volts
1
µa
No Ring Signal Present
38
150
RMS Type B Ringer
15.3
68
Hz Type B Ringer
20
Volts DC Battery Voltage level detected by
circuit shown on Page 10
1.0
Volts DC Change in Battery Voltage
detected by circuit shown on
Page 10
10
40
100
ma
600
Ohms
-12
-10
-9
dBm
-2.5
0
dBm Avg over 3 second interval
2.4
Volts
0.4
Volts
2.0
VCC+0.3 Volts
-0.3
0.8
Volts
XE2420 ABSOLUTE MAXIMUM RATINGS
Storage Temperature
Operating Temperature Range1
Maximum Time Above Eutectic (183O C)
-25O C to +85O C
0O C to +70O C
90 seconds
Preheat Dwell Time 120 to 180 seconds
1 The XE2420 can be ordered with an Operating Temperature of -40O C to +85O C at extra cost. Order XE2420-ITR or
to specify Industrial Temperature Range (ITR).