RTL8139C(L)
6.22 Auto-negotiation Expansion Register
(Offset 006Ah-006Bh, R)
This register contains additional status for NWay auto-negotiation.
Bit
Name
Description/Usage
Default/ Attribute
15-5
-
Reserved. These bits are always set to 0.
-
4
MLF
Status indicating if a multiple link fault has occurred.
0, RO
1 = fault occurred; 0 = no fault occurred.
3
LP_NP_ABLE Status indicating if the link partner supports Next Page negotiation.
0, RO
1 = supported; 0 = not supported.
2
NP_ABLE This bit indicates if the local node is able to send additional Next
0, RO
Pages.
1
PAGE_RX This bit is set when a new Link Code Word Page has been received.
0, RO
The bit is automatically cleared when the auto-negotiation link
partner’s ability register (register 5) is read by management.
0
LP_NW_ABLE 1 = link partner supports NWay auto-negotiation.
0, RO
6.23 Disconnect Counter
(Offset 006Ch-006Dh, R)
Bit
Name
Description/Usage
15-0
DCNT
This 16-bit counter increments by 1 for every disconnect event. It rolls
over when becomes full. It is cleared to zero by read command.
Default/ Attribute
h'[0000],
R
6.24 False Carrier Sense Counter
(Offset 006Eh-006Fh, R)
This counter provides information required to implement the “False Carriers” attribute within the MAU managed object class of
Clause 30 of the IEEE 802.3u specification.
Bit
Name
Description/Usage
Default/ Attribute
15-0
FCSCNT This 16-bit counter increments by 1 for each false carrier event. It is
h'[0000],
cleared to zero by read command.
R
6.25 NWay Test Register
(Offset 0070h-0071h, R/W)
Bit
Name
Description/Usage
15-8
-
Reserved
7
NWLPBK 1 = set NWay to loopback mode.
6-4
-
Reserved
3
ENNWLE 1 = LED0 Pin indicates linkpulse
2
FLAGABD 1 = Auto-neg experienced ability detect state
1
FLAGPDF 1 = Auto-neg experienced parallel detection fault state
0
FLAGLSC 1 = Auto-neg experienced link status check state
Default/ Attribute
-
0, RW
-
0, RW
0, RO
0, RO
0, RO
2002/01/10
28
Rev.1.4