PRELIMINARY
Table 3. Am29DL800BB Bottom Boot Sector Architecture
Bank
Sector
Sector Address
Bank Address
A18 A17 A16 A15 A14 A13 A12
Sector Size
(Kbytes/
Kwords)
(x8)
Address Range
(x16)
Address Range
SA21 1 1 1 1 X X X
SA20 1 1 1 0 X X X
64/32
64/32
F0000h–FFFFFh
E0000h–EFFFFh
78000h–7FFFFh
70000h–77FFFh
SA19 1 1 0 1 X X X
64/32
D0000h–DFFFFh 68000h–6FFFFh
SA18 1 1 0 0 X X X
64/32
C0000h–CFFFFh 60000h–67FFFh
SA17 1 0 1 1 X X X
64/32
B0000h–BFFFFh 58000h–5FFFFh
SA16 1 0 1 0 X X X
64/32
A0000h–AFFFFh 50000h–57FFFh
SA15 1 0 0 1 X X X
Bank 2
SA14 1 0 0 0 X X X
SA13 0 1 1 1 X X X
SA12 0 1 1 0 X X X
SA11 0 1 0 1 X X X
SA10 0 1 0 0 X X X
SA9 0 0 1 1 X X X
SA8 0 0 1 0 X X X
64/32
64/32
64/32
64/32
64/32
64/32
64/32
64/32
90000h–9FFFFh
80000h–8FFFFh
70000h–7FFFFh
60000h–6FFFFh
50000h–5FFFFh
40000h–4FFFFh
30000h–3FFFFh
20000h–2FFFFh
48000h–4FFFFh
40000h–47FFFh
38000h–3FFFFh
30000h–37FFFh
28000h–2FFFFh
20000h–27FFFh
18000h–1FFFFh
10000h–17FFFh
SA7 0 0 0 1 1 1 X
16/8
1C000h–1FFFFh 0E000h–0FFFFh
10X
SA6 0 0 0 1
01X
32/16
18000h–1BFFFh
14000h–17FFFh
0C000h–0DFFFh
0A000h–0BFFFh
SA5 0 0 0 1 0 0 1
8/4
12000h–13FFFh
09000h–09FFFh
SA4 0 0 0 1 0 0 0
8/4
10000h–11FFFh
08000h–08FFFh
Bank 1
SA3 0 0 0 0 1 1 1
8/4
0E000h–0FFFFh 07000h–07FFFh
SA2 0 0 0 0 1 1 0
10X
SA1 0 0 0 0
01X
SA0 0 0 0 0 0 0 X
8/4
32/16
16/8
0C000h–0DFFFh
08000h–0BFFFh,
04000h–07FFFh
00000h–03FFFh
06000h–06FFFh
04000h–05FFFh,
02000h–03FFFh,
00000h–01FFFh
Note: The address range is A18:A-1 if in byte mode (BYTE# = VIL). The address range is A18:A0 if in word mode (BYTE# = VIH).
Autoselect Mode
The autoselect mode provides manufacturer and de-
vice identification, and sector protection verification,
through identifier codes output on DQ7–DQ0. This
mode is primarily intended for programming equipment
to automatically match a device to be programmed with
its corresponding programming algorithm. However,
the autoselect codes can also be accessed in-system
through the command register.
When using programming equipment, the autoselect
mode requires VID (11.5 V to 12.5 V) on address pin
A9. Address pins A6, A1, and A0 must be as shown in
Table 4. In addition, when verifying sector protection,
the sector address must appear on the appropriate
highest order address bits (see Tables 2 and 3). Table
4 shows the remaining address bits that are don’t care.
When all necessary bits have been set as required, the
programming equipment may then read the corre-
sponding identifier code on DQ7-DQ0.
To access the autoselect codes in-system, the host
system can issue the autoselect command via the
command register, as shown in Table 5. This method
does not require VID. Refer to the Autoselect Command
Sequence section for more information.