datasheetbank_Logo
búsqueda de Hoja de datos y gratuito Fichas de descarga

CS5360 Ver la hoja de datos (PDF) - Cirrus Logic

Número de pieza
componentes Descripción
Lista de partido
CS5360 Datasheet PDF : 22 Pages
First Prev 11 12 13 14 15 16 17 18 19 20 Next Last
CS5360
4.2 Bar Graph Mode
This mode provides a decoded output format which
indicates the peak Peak Signal Level in a "Bar
Graph" format.
Input Level
Overflow
0 dB to -3 dB
-3 dB to -6 dB
-6 dB to -10 dB
-10 dB to -20 dB
-20 dB to -30 dB
-30 dB to -40 dB
-40 dB to -60 dB
< - 60 dB
P7 - P0
11111111
01111111
00111111
00011111
00001111
00000111
00000011
00000001
00000000
Table 4. P7 to P0 - Peak Signal Level Bits -Bar Graph
Mode
4.3 Overflow
Overflow indicates analog input overrange for the
Left and Right channels as of the last update re-
quest on the Peak Update pin. A value of 1 indi-
cates an overrange condition. The left channel
information is output on OVFL during the left
channel portion of LRCK. The right channel infor-
mation is available on OVFL during the right chan-
nel portion of LRCK.
4.4 Initialization
Upon initial power-up, the digital filters and delta-
sigma modulators are reset and the internal voltage
reference is powered down. The CS5360 will re-
main in the power-down mode until valid clocks
are presented. A valid MCLK is required to exit
power-down in Master Mode. However, in Slave
Mode, MCLK and LRCK of the proper ratio are re-
quired to exit power-down. MCLK occurrences are
also counted over one LRCK period to determine
the MCLK / LRCK frequency ratio in Slave Mode.
Power is then applied to the internal voltage refer-
ence, the analog inputs will move to approximately
2.2 V and output clocks will begin (Master Mode
only). This process requires 32 periods of LRCK
and is followed by the initialization sequence.
4.5 Initialization with High Pass Filter
Enabled
28,672 LRCK cycles are required for the initializa-
tion sequence with the high pass filter enabled.
This time is dominated by the settling time required
for the high pass filter.
4.6 Initialization and Internal
Calibration with High Pass Filter
Disabled
If the HP DEFEAT pin is high (high pass filter dis-
abled) during the initialization sequence, the
CS5360 will perform an internal dc calibration by:
1) disconnecting the internal ADC inputs from the
input pins,
2) connecting the (differential) ADC inputs to a
common reference voltage,
3) running the high pass filter with a fast settling
time constant,
4) freezing the dc offset register, and
5) reconnecting the internal ADC inputs to the in-
put pins.
This procedure takes 4,160 cycles of LRCK. Un-
like the system calibration procedure described in
the High Pass Filter section, a dc calibration per-
formed during start-up will only eliminate offsets
internal to the CS5360, and should result in output
codes which accurately reflect the differential dc
signal at the pins.
DS280PP2
13

Share Link: 