datasheetbank_Logo
búsqueda de Hoja de datos y gratuito Fichas de descarga

AD8150(Rev0) Ver la hoja de datos (PDF) - Analog Devices

Número de pieza
componentes Descripción
Lista de partido
AD8150
(Rev.:Rev0)
ADI
Analog Devices ADI
AD8150 Datasheet PDF : 35 Pages
First Prev 11 12 13 14 15 16 17 18 19 20 Next Last
AD8150
Control Interface Truth Tables
The following are truth tables for the control interface.
Reset CS
0
X
1
1
1
0
1
0
1
0
1
0
Control Pins
WE RE Update
X
X
X
X
X
X
0
X
X
X
0
X
X
X
0
0
1
0
Table I. Basic Control Functions
Function
Global Reset. Reset all second rank enable bits to zero (disable all outputs).
Control Disable. Ignore all logic (but the signal matrix still functions as
programmed). D[6:0] are high-impedance.
Single Output Preprogram. Write input configuration data from data bus D[6:0].
into first rank of latches for the output selected by the output address bus A[4:0].
Single Output Readback. Readback input configuration data from second rank of latches
onto data bus D[6:0] for the single output selected by the output address bus A[4:0].
Global Update. Copy input configuration data from all 17 first rank latches into second
rank of latches, updating signal matrix connections for all outputs.
Transparent Write and Update. It is possible to write data directly onto rank two. This
simplifies logic when synchronous signal matrix updating is not necessary.
Table II. Address/Data Examples
Output Address Pins Enable
MSB–LSB
Bit
Input Address Pins
MSB-LSB
A4 A3 A2 A1 A0 D6/E D5 D4 D3 D2 D1 D0
00000X
000000
10000X
100000
<Binary Output Number*> 1
<Binary Input Number>
<Binary Output Number*> 0
10001X
XXXXXX
<Binary Input Number>
10010X
100001
*The binary output number may also be the broadcast connection designator, 10001X.
Function
Lower Address/Data Range. Connect Output #00
(A[4:0] = 00000) to Input #00 (D[5:0] = 000000).
Upper Address/Data Range. Connect Output #16
(A[4:0] = 10000) to Input #32 (D[5:0] = 100000).
Enable Output. Connect Selected Output (A[4:0] = 0
to 16) to Designated Input (D[5:0] = 0 to 32) and
Enable Output (D6 = 1).
Disable Output. Disable Specified Output (D6 = 0).
Broadcast Connection. Connect all 17 outputs to
same designated input and set all 17 enable bits to
the value of D6. Readback is not possible with the
broadcast address.
Reserved. Any address or data code greater or equal
to these are reserved for future expansion or factory
testing.
–12–
REV. 0

Share Link: 

datasheetbank.com [ Privacy Policy ] [ Request Datasheet ] [ Contact Us ]